1. E2E2E2E2E2E2E2E2E2E2E2E2E2E2Compact Light FittingSeries C-LUX 6100 / 6500www.stahl.de Lighting E2/1 2012-08-21·EK00·III·enSeries C-LUX 6100 / 6500 E201907E00WebCode 6100A> Suitable for wall or ceilingmounting> Can be fitted to order withemergency exit signs> Central locking> All-pole disconnection via N/Cswitch when cover is opened(Series 6100)Series C-LUX 6100 and 6500 compact light fittings can be used fornormal lighting, but also as information fittings or as group- orcentrally-powered emergency lights.*) only 6100ATEX / GOST*Zone 0 1 2 20 21 22C-LUX 6100: For use in x x x xC-LUX 6500: For use in x x x 2. Compact Light FittingSeries C-LUX 6100 / 6500Selection TableVersion Lamps Lamps Electronic ballasts Order number Weightpiece kgC-LUX 6100Zones 1, 21Fluorescent lamp 1 x 8 W 1 6100/1081-8011-3430-00 3.3902 x 8 W 1 6100/1082-8011-3430-00 3.5002 6100/1082-9011-3430-00 2.4003 x 8 W 1 6100/1083-8011-3430-00 3.5302 6100/1083-9011-3430-00 2.600C-LUX 6500Zones 2, 21, 22Fluorescent lamp 1 x 8 W 1 6500/1081-8010-8430-00 2.4002 x 8 W 2 6500/1082-9010-8430-00 2.5003 x 8 W 3 6500/1083-9010-8430-00 2.600DULUX-L lamp 1 x 24 W 1 6500/3241-8010-2430-00 2.400Incandescent lamp 1 x 60 W - - 6500/6601-0010-0430-00 2.1502 x 40 W - - 6500/6402-0010-0430-00 2.300Order Number SupplementCable entries 6.00/....-..1.-....-..6.00/....-..9.-....-..Standard: 1 x cable gland M25 x 1.52 x stopping plugs M25 x 1.5Special: Specify non-standard entries in writingMonitoring module without 6.00/....-....-...0-..with 6.00/....-....-...2-..Emergency exit6.00/....-....-....-006.00/....-....-....-606.00/....-....-....-616.00/....-....-....-62needed only when used as information lights or escapesign lights;With adhesive symbols positioned as follows:Mounting positionStandard08481E00Special please specify other positions in writingPlease specify emergency exit sign number (seebelow)Symbol complying with VGB 125, DIN 4844, DIN 5035;recognition distance e = 30 m; size 150 x 355 mmwithout emergency exit sign08483E00Colours SignBackgroundwhitegreen08482E00Colours SignBackgroundwhitegreen08484E00Colours SignBackgroundwhitegreenE2/2 Lighting 2012-08-21·EK00·III·en 3. E2E2E2E2E2E2E2E2E2E2E2E2E2E2Compact Light FittingSeries C-LUX 6100 / 6500Order Number SupplementEmergency exit 6.00/....-....-....-916.00/....-....-....-716.00/....-....-....-816.00/....-....-....-926.00/....-....-....-726.00/....-....-....-826.00/....-....-....-906.00/....-....-....-706.00/....-....-....-806.00/....-....-....-936.00/....-....-....-736.00/....-....-....-8308485E00Colours SignBackgroundwhitegreen03206E00Colours SignBackgroundgreenwhite12617E00Colours SignBackgroundredwhite08486E00Colours SignBackgroundwhitegreen09020E00Colours SignBackgroundgreenwhite12618E00Colours SignBackgroundredwhite08487E00Colours SignBackgroundwhitegreen03203E00Colours SignBackgroundgreenwhite12616E00Colours SignBackgroundredwhite08488E00Colours SignBackgroundwhitegreen12615E00Colours SignBackgroundgreenwhite12619E00Colours SignBackgroundredwhiteNote Compact light fittings can be operated as emergency lighting via a group or central battery system;fittings are supplied without lamps, which must be ordered separately; further escape and informationsigns available on request.2012-08-21·EK00·III·en Lighting E2/3 4. Compact Light FittingSeries C-LUX 6100 / 6500Explosion ProtectionEurope (ATEX)Version 6100 (Zones 1, 21) 6500 (Zones 2, 21, 22)Gas Zone 1: PTB 97 ATEX 2119 Zone 2: SNCH 03 ATEX 3558Zone 1: E II 2 G EEx eds IIC T4 Zone 2: E II 3 G EEx n A II T4 (T3 forincandescent lamps)Dust Zone 21: LCIE 03 ATEX 6158 Zone 21: SNCH 03 ATEX 3557Zone 22: SNCH03 ATEX 3558Zone 21: E II 2 D IP66 T130°C Zone 21: E II 2 D IP66 T1)Zone 22: E II 3 DIP66 T1)1) T85 °C for 8 W lamps; T68 °C forDULUX L lamps; T117 °C for incandescentlampsCertificates and approvalsVersion 6100 (Zones 1, 21) 6500 (Zones 2, 21, 22)Certificates ATEX, Canada (CSA), Kazakhstan (GOST-K),Russia (GOST-R), Serbia (IZP), Belarus(GOST-B)ATEX, China (CQST), Canada (CSA), Russia(GOST-R), Serbia (IZP), Ukraine (GOST-U),USA (FM), Belarus (GOST-B)Technical DataElectrical dataRated voltagefor fluorescent lamps: AC: 220 (- 10%) ... 240 (+ 10%) V; 50 / 60 HzDC: 198 ... 250 Vfor DULUX-L lamps: AC: 220 (- 10%) ... 240 (+ 6%) V; 50 / 60 HzDC: 176 ... 254 Vfor incandescent lamps: 230 VVersion 6100 (Zones 1, 21) 6500 (Zones 2, 21, 22)Disconnectionof light fitting onopeningCentral locking device with safety interlock;switch 8080 with N/C contacts;when central lock is opened, voltage to ballastis disconnected on both poles;a safety interlockin switching mechanism prevents fitting frombeing reconnected while cover and central lockare open.Standard light fitting 6500: without swtching offFaulty lamp If lamp is faulty power supply is automatically switched off by electronic ballastLuminous CharacteristicsLampsFluorescent lamps DULUX-L Incandescent lampsNumber oflamps1 x 8 W 2 x 8 W 3 x 8 W 1 x 24 W 1 x 60 W 2 x 40 WElectronicballast1 1 2 1 2 1 - - - -Rated current 0.088 A 0.135 A 0.176 A 0.2 A 0.223 A 0.11 A 0.30 A 0.39 ALight guides Reflector painted white;Cover with prism structure providing directed light from fittingOperating modes Mains operation for general lighting or as information lights.Emergency light operation, supplied from group or central battery system for emergency orescape route lighting.Ambient conditionsVersion 6100 (Zones 1, 21) 6500 (Zones 2, 21, 22)Ambient temperature -20 ... +50 °C -20 ... +50 °C (with fluorescent lamp)-20 ... +40 °C (with DULUX-L lamp)-50 ... +40 °C (with incandescent lamp)Mechanical dataDegree of protection IP66 (IP64 with breather 8162)Protection class I(with internal PE connection terminal)MaterialEnclosure glass fibre reinforced polyester resincolour: white, similar to RAL 9010Lamp cover PolycarbonateSeal Polyurethane; foamed into coverCover options Central locking using socket spanner M8 / SW 13; cover hinged for access08478E02central lock cover hingeE2/4 Lighting 2012-08-21·EK00·III·en 5. E2E2E2E2E2E2E2E2E2E2E2E2E2E2Compact Light FittingSeries C-LUX 6100 / 6500Technical DataAssembly / InstallationCable entryStandard 1 cable entry 8161 in plastic, M25 x 1.5 and2 plugs 8290 in plastic, M25 x 1.5(enclosed)Special version Other entries in moulded plastic or metal are available to order - details available on request.ConnectionTerminal size 2 x 4 mm2 for solid cores2 x 2.5 mm2 for flexible coresMarking L, N, PETerminal block in polyamide with coverInstallation notesMounting Can be wall- or ceiling-mountedLooping through ofcables2 leads can be connected to each terminal on the input side, making fittings suitable for loopedconnectionMonitoring moduleFunction Monitoring and switching module for emergency light systems according to VDE 0108:08480E00The module is used for the monitoring of individual lights and for the control of network and safetylights.The module offers the following functions:• Control of the light (ON / OFF) and function test• Up to 20 addresses can be set for each electric circuit by means of a coding switch• The operating mode of the lamp (continuous light, stand-by light or activation by means of aswitch) is freely programmable• Mixed operation within one circuit is possibleInput voltage (Input between L+ and N-)UN 230 (+ 10 % / - 15 %) V AC, 50 HzU DC 175 ... 275 V DCControl input (between L and N)Connected power (outputto light)Ambient temperatureUN 230 (+ 10 % / - 15 %) V AC, 50 HzP 4 ... 100 WTa (Modu-le)- 10 ... + 50 °CDimensions L x W x H = 95 x 40 x 32 mmEmergency exit signsUse for information and escape sign fittingsMaterial Foil, self-adhesive, printed with various pictograms in different coloursMounting Foil is stuck to cover externallyOptions The various types of adhesive foil which can be supplied are detailed in table "Accessories andSpare parts"Recognition distance e = 30 mDimensions see dimensional drawings2012-08-21·EK00·III·en Lighting E2/5 6. Compact Light FittingSeries C-LUX 6100 / 6500Accessories and Spare PartsDesignation Illustration Description Order number WeightkgFluorescent lamps04936E008 W, d 16 mm, for two-pin G5 holder 0.000119045 0.415Socket spanner05321E00Colour oflightLight fluxcool white 450 Im 10 pcsM8 / wrench size 13;to open/close the central locking140486 0.126Adapter plate05755E00for use together with metal cable glands; the metal cableglands are integrated in the earthing system via adapterplates115826 0.060115828 0.060Emergency exit sign08483E00113182 0.01508482E00113183 0.01508484E00113184 0.01508485E00113210 0.01503206E00113193 0.01512617E00113200 0.01508486E00113211 0.01509020E00113194 0.01512618E00113201 0.01508487E00113209 0.01503203E00113192 0.01512616E00113199 0.0152 x M20 x 1.5 1 piece2 x M25 x 1.5 1 pieceAdhesive foil:size:150 x 355 mmrecognition distance:e = 30 mColour:Symbol/Text Backgroundwhite green 1 pcwhite green 1 pcwhite green 1 pcwhite green 1 pcgreen white 1 pcred white 1 pcwhite green 1 pcgreen white 1 pcred white 1 pcwhite green 1 pcgreen white 1 pcred white 1 pcE2/6 Lighting 2012-08-21·EK00·III·en 7. E2E2E2E2E2E2E2E2E2E2E2E2E2E2Compact Light FittingSeries C-LUX 6100 / 6500Accessories and Spare PartsDesignation Illustration Description Order number WeightkgEmergency exit sign 0.00008488E00113212 0.01512615E00113195 0.01512619E00113202 0.015Diffuser05704E00Adhesive foil:size:recognition distance:150 x 355 mme = 30 mColour:Symbol/Text Backgroundwhite green 1 pcgreen white 1 pcred white 1 pcfor light fitting 8 W 119044 0.250Dimensional Drawings (All Dimensions in mm) - Subject to Alterations7 11904293E00Additional dimensions for cableentries 8161 and plugs 829004295E00355150Emergency exit sign9 425 11445181 a4R3,5a (mm)8161 M25 x 1.5 328290 M25 x 1.5 6We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice.The illustrations cannot be considered binding.2012-08-21·EK00·III·en Lighting E2/7
Comments
Report "Stahl 6100/6500 Compact Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area Lighting"