Bulk Cable / Custom Cable Assemblies / Cable Management Products /Small Panel Assembly Get it Started and Stay Connected. CABLE GUIDE Contents COMPANY OVERVIEW ............................................................................................................................... 4 CONTACT INFORMATION .......................................................................................................................... 7 8 AWG Cable Specifications....................................................................................................................... 8 8 AWG / 4C ............................................................................................................................................ 9 10 AWG Cable Specifications .................................................................................................................. 10 10 AWG / 3C ........................................................................................................................................ 11 10 AWG / 4C ........................................................................................................................................ 12 10 AWG / 6C ........................................................................................................................................ 13 12 AWG Cable Specifications .................................................................................................................. 14 12 AWG / 3C ........................................................................................................................................ 15 12 AWG / 4C ........................................................................................................................................ 16 12 AWG / 4C ........................................................................................................................................ 17 12 AWG / 7C ........................................................................................................................................ 18 14 AWG Cable Specifications .................................................................................................................. 19 14 AWG / 3C ........................................................................................................................................ 20 14 AWG / 3C ........................................................................................................................................ 21 14 AWG / 4C ........................................................................................................................................ 22 14 AWG / 4C ........................................................................................................................................ 23 14 AWG / 5C ........................................................................................................................................ 24 14 AWG / 7C ........................................................................................................................................ 25 16 AWG Cable Specifications .................................................................................................................. 26 16 AWG / 3C ........................................................................................................................................ 27 16 AWG / 3C ........................................................................................................................................ 28 16 AWG / 4C ........................................................................................................................................ 29 16 AWG / 4C ........................................................................................................................................ 30 16 AWG / 7C ........................................................................................................................................ 31 16 AWG / 7C ........................................................................................................................................ 32 16 AWG / 7C ........................................................................................................................................ 33 16 AWG / 7C ........................................................................................................................................ 34 16 AWG / 12C ...................................................................................................................................... 35 16 AWG / 12C ...................................................................................................................................... 36 16 AWG / 12C ...................................................................................................................................... 37 16 AWG / 18C ...................................................................................................................................... 38 16 AWG / 19C ...................................................................................................................................... 39 16 AWG / 25C ...................................................................................................................................... 40 16 AWG / 25C ...................................................................................................................................... 41 16 AWG / 33C ...................................................................................................................................... 42 16 AWG / 37C ...................................................................................................................................... 43 22 AWG Cable Specifications .................................................................................................................. 44 22 AWG / 24C ...................................................................................................................................... 45 Communication / Shielded Cable Specifications ..................................................................................... 46 20 AWG / 3C ........................................................................................................................................ 47 20 AWG / 2 PR ..................................................................................................................................... 48 20 AWG / 3 PR ..................................................................................................................................... 49 20 AWG / 16 PR ................................................................................................................................... 50 22 AWG / 3 PR ..................................................................................................................................... 51 22 AWG / 3 PR ..................................................................................................................................... 52 22 AWG / 17 PR ................................................................................................................................... 53 22 AWG / 37 PR ................................................................................................................................... 54 Hybrid / Composite Cable Specifications ................................................................................................ 55 16AWG/1PR 22AWG/3PR .................................................................................................................... 56 14AWG/4C | 18AWG/2PR ................................................................................................................... 56 COMPANY OVERVIEW Get Started with Electrivert. Automation equipment doesn’t run by itself. It needs power. Electrivert helps deliver that power with top quality, NFPA-79 certified, control and power cables – customized for your specific applications. As a leading manufacturer and full-service provider of molded and custom cable assemblies, Electrivert works with companies across the U.S. – meeting and exceeding their interconnect needs for industrial machinery and factory automation. Flexible and Fast Electrivert has built a “reputation of excellence” by adhering to a simple philosophy…we listen. We work with you to match a solution to your requirements. Whether it’s a planned application or last minute request, we’re flexible and fast enough to get it done on time and on budget. And, our in-house engineering and testing teams ensure that all products meet and exceed industry standards – as well as your expectations. That’s why we’re the preferred supplier for top quality custom cable assemblies. Our Mission – To be the Best! At Electrivert, our goal is to be your best source for custom cable assemblies: • Outstanding service and support • Engineering expertise in design innovations • Manufacturing capabilities that offer mechanical and molded assemblies • A Flexible work force to service you more effectively and efficiently • Approved as a government build source (U.S. Government CAGE CODE 08 NE8) • ISO 9002 registered • Free local shipping • Made in the USA Every product is 100% tested and defect free. Electrivert PERFORMANCE PLUS™ Molded Industrial Cables Electrivert’s PERFORMANCE PLUS™ molded cable assemblies are available as both straight and 90° configurations and are rated to IP65 and NEMA 12 when mated to DIN 43652 receptacles. And, our diecast shells use ElectriLatch™, instead of pins, which makes it more resistant to shock and vibration. Nickel-plating offers increased conductivity, improved corrosion resistance and better appearance. PERFORMANCE PLUS™ molded cable assemblies are also engineered to comply with and meet GM NCCC-3 specifications for automotive control cables. Features and Benefits: • Two-stage molding process ensures a high quality product that reduces downtime and maintenance costs, improves process quality and reduces installation times • Tamper-proof to ensure the reliability and uptime of any installation • Designed to eliminate conductor stress and contact push back to help reduce system failures • 250 lbs pull out force ratings improve system reliability and eliminate intermittent connection issues • Omni-directional flex strain relief reduces installation and maintenance issues • Overmolding process ensures reliable connections in harsh environments, including IP65 • Rugged design decreases downtime and maintenance costs related to damaged hoods or latch pins • Availability in standard and custom lengths to facilitate your design process and reduce procurement costs • Fewer components to provide quick turnaround and delivery times • Availability in Flex or Static/Tray for total design flexibility • Made in Michigan, supporting local manufacturing Get it Started and Stay Connected. Custom Cable Assemblies DISTRIBUTION PRODUCTS Electrivert is also a leading distributor for Harting rectangular connectors, Remke mini and micro machine tool cords and Mohawk/Alpha custom cable. This distribution rela- tionship allows us to give our customers faster turnaround time for either kits or custom built assemblies. Harting Han® Industrial Cable Assemblies These multi-pin connectors utilize robust metal hoods and housings for protection from dust, liquids and physical damage. • UL and CSA approved • NEMA Type 4/12 Rating • Flexible conduit and jacketed cable • IP 68 protection available • Power and signal combinations Remke Tuff-Seal™ Wire Management Products Remke’s wire management products include strain relief cord connectors in a variety of sizes and styles, wire mesh grips, corrosion-resistant and liquid-tight connectors. The rugged cord grips, conduit adapters and basketweaves protect cable from damage and environmental concerns. • Can be customized to fit your specific needs • Your choice of NPT, Pg or Metric threads. • Meet UL and CSA specifications for keeping out oil, water, dirt and other contaminants. Remke Tuff-Link™ Molded Connectors and Cordsets Remke’s full-line of mini, micro (M12) and pico (M8) tool cords are manufactured to indus- try standards along with various splitters, distribution boxes and accessories. They are used as the interconnect for sensors, actuators and other control devices in automated manufacturing and production equipment. • Can be customized to fit your specific needs Mohawk/Alpha Cable Products Mohawk’s cables meet all of your factory automation applications – from power to control to communication. We can work with you to develop and engineer a cable to meet your specific needs. • All 600V cables are manufactured to meet NFPA-79 specifications. • Meets and supports TIA/EIA, ISO/IEC, ICEA and NEMA standards. Contact us today, toll-free, at 877-768-5535 or email us at
[email protected] to discover how we can help you get it started and stay connected. Custom Cable Assemblies 17850 14 Mile Road Fraser, MI 48026-2271 877-768-5535 Toll-Free Phone: 586-285-0720 Fax: 586-285-0742
[email protected] www.electrivert.com Made with Pride in the USA CONTACT INFORMATION Mailing Address: 17850 14 Mile Road Fraser, MI 48026-2271 Toll Free: (877) 768-5535 Local Telephone: (586) 285-0720 Fax: (586) 285-0742 General E-mail:
[email protected] Website: www.electrivert.com Sales: Ken Murphy – (586) 764-5874 Jody Williquette – (586) 489-1818 Customer Service & Estimating Terri Berliner – (586) 285-0720 x 131 Gary Ellingham – (586) 285-0720 x 135 Production and Mfg: Bonny Letlow – (586) 285-0720 x 127 8 AWG Cable Specifications INSULATION: .032” (.81 mm) OF 105°C PVC TEMP. RANGE: -25°C TO +105°C NOMINAL DIAMETER: .251” (6.37 mm) APPLICATIONS 9.0” LEFT HAND LAY 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT TRAYS - EXPOSED RUNS LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 4 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40185 8 AWG / 4C Jacket Insulation Conductor Barrier CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 8 AWG (8.60 mm²) (168/30) BARE CABLE WEIGHT: 390 lbs/1000ft (573 kg/km) COPPER BENDING RADIUS: 7.4” (188 mm) MIN (10 x CABLE OD) SHEATH: .0055” (.14 mm) OF NYLON RECOMMENDED CABLE ASSEMBLY: 4 CONDUCTORS CABLED WITH FILLERS IN A BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: ORANGE THERMOPLASTIC ELASTOMER • MACHINE TOOLS NOMINAL OD: .740” (18.80 mm) • MATERIAL HANDLING EQUIPMENT RATINGS/ UL TYPE TC-ER - 90°C, 600V • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE CE / LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDUCTOR #1-#3: BLACK W/WHITE NUMBER PRINTING CONDUCTOR #4: GREEN W/YELLOW STRIPE PRINT LEGEND: MOHAWK E163873 M58150 8 AWG (8.60 mm sq) 4 COND - UL 1277 TC-ER - 600V THHN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40185 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADD M#, K# , OPEN WIRING; CHANGE TEMP RANGE 02/26/02 WL B ADD mm sq TO PRINT 06/03/03 VB C UPDATE HEADER/FOOTER, LISTINGS, PRINT 02/03/05 JS D CHG TEMPS, PRINT, APPLICATIONS; ADDED ROHS 11/07/07 VB Date: 07/03/01 Page 1 of 1 Part Number: M58150 Orig: Review: 10 AWG Cable Specifications SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL WALL: .052" (1.32 mm) TRAYS - EXPOSED RUNS RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V ELECTRICAL CHARACTERISTICS CONDUCTOR #2: WHITE W/YELLOW STRIPE CONDUCTOR DCR: .33 Ω/100m (1.02 Ω/Mft) MAX Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 3 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40194 10 AWG / 3C Jacket Insulation Conductor Barrier CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 10 AWG (5.32 mm2) (105/30) BARE COPPER CABLE WEIGHT: 180 lbs/1000ft (268 kg/km) INSULATION: .022” (.56 mm) OF 105°C PVC BENDING RADIUS: 4.9” (124 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .172” (4.37 mm) RECOMMENDED ASSEMBLY: 3 CONDUCTORS CABLED TOGETHER IN A 4.75” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT NOMINAL OD: .494” (12.55 mm) • MATERIAL HANDLING EQUIPMENT LISTINGS/ UL TYPE TC-ER - 90°C, 600V • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE CE - LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDUCTOR #1: RED W/YELLOW STRIPE CONDUCTOR #3: GREEN W/YELLOW STRIPE PRINT LEGEND: MOHAWK E163873 M 10 AWG (5.32 mm sq) 3 COND - UL 1277 TC-ER - 600V THHN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40194 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. Date: 05/14/08 Page 1 of 1 Part Number: - Orig: Review: SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .559” (14.20 mm) • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V TRAYS - EXPOSED RUNS CONDUCTOR DCR: .33 Ω/100m (1.02 Ω/Mft) MAX CONDUCTOR #4: GREEN W/YELLOW STRIPE Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 4 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40178 10 AWG / 4C Jacket Insulation Conductor Barrier CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 10 AWG (5.31 mm²) (105/30) BARE COPPER CABLE WEIGHT: 252 lbs/1000ft (375 kg/km) INSULATION: .022” (.56 mm) OF 105°C PVC BENDING RADIUS: 5.6” (142 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .172” (4.37 mm) RECOMMENDED ASSEMBLY: 4 CONDUCTORS CABLED WITH FILLERS IN A 5.5” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: ORANGE THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT LISTINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE / LOW VOLTAGE DIRECTIVE • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE ELECTRICAL CHARACTERISTICS CONDUCTOR COLOR CODE CONDUCTOR #1-#3: BLACK W/WHITE NUMBER PRINTING PRINT LEGEND: MOHAWK E163873 M58099 - 10 AWG (5.31 mm sq) 4 COND UL 1277 TC-ER - 600V THHN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40178 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. D UPDATE HEADER/FOOTER, LISTINGS, PRINT 02/03/05 JS E ADDED ROHS INFOR AND MODIFIED TEMP RATING 06/27/07 VB F UPDATE HDR, BEND RADIUS, APPLICATIONS 07/20/07 BA G CHG RECOMMENDED TEMP RANGE TO 90°C 08/03/07 BA Date: 04/27/01 Page 1 of 1 Part Number: M58099 Orig: Review: SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .660” (16.76 mm) • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V TRAYS - EXPOSED RUNS CONDUCTOR DCR: .33 Ω/100m (1.02 Ω/Mft) MAX CONDUCTOR #2: BLUE W/WHITE STRIPE Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 6 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40237 10 AWG / 6C JACKET CONDUCTOR INSULATION BARRIER TAPE CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 10 AWG (5.31 mm²) (105/30) BARE COPPER CABLE WEIGHT: 358 lbs/1000ft (533 kg/km) INSULATION: .022” (.56 mm) OF 105°C PVC BENDING RADIUS: 6.6” (168 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .172” (4.37 mm) RECOMMENDED ASSEMBLY: 6 CONDUCTORS CABLED AROUND A FILLER IN A 6.75” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT LISTINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE / LOW VOLTAGE DIRECTIVE • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE ELECTRICAL CHARACTERISTICS CONDUCTOR COLOR CODE CONDUCTOR #1: BLUE CONDUCTOR #3: GREEN W/YELLOW STRIPE, NUMBERED #1 CONDUCTOR #4: RED CONDUCTOR #5: WHITE CONDUCTOR #6: GREEN W/YELLOW STRIPE, NUMBERED #2 PRINT LEGEND: MOHAWK E163873 M58911 - 10 AWG (5.31 mm sq) 6 COND UL 1277 TC-ER - 600V THHN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40237 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADD K # TO PRINT 10/15/09 JS Date: 07/22/09 Page 1 of 1 Part Number: M58911 Orig: Review: 12 AWG Cable Specifications SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO + 90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .410” (10.41 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR #2: WHITE W/BLACK NUMBER PRINTING Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 3 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40223 12 AWG / 3C Jacket Insulation Conductor Barrier Filler CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 12 AWG (3.29mm2) (65/30) BARE COPPER CABLE WEIGHT: 128 lbs/1000ft (190 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.1” (104 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .135” (3.43 mm) RECOMMENDED ASSEMBLY: 3 CONDUCTORS CABLED WITH FILLERS IN A 3.75” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1: RED W/BLACK NUMBER PRINTING CONDUCTOR DCR: .55 Ω/100m (1.67 Ω/Mft) MAX CONDUCTOR #3: GREEN W/YELLOW STRIPE PRINT LEGEND: MOHAWK E163873 M58832 - UL 1277 TC-ER - 600V THHN (UL) 12 AWG (3.29 mm sq) 3 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40223 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADJ DIA & DCR; CORRECT STRANDING 03/28/08 JS B ADD M # & K # 04/07/08 JS Date: 03/26/08 Page 1 of 1 Part Number: M58832 Orig: Review: SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR #4: GREEN W/YELLOW STRIPE Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 4 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40201 12 AWG / 4C Jacket Braid Insulation Conductor Barrier Separator CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 12 AWG (3.29 mm2) (65/30) BARE COPPER CABLE WEIGHT: 187 lbs/1000ft (278 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 5.0” (128 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .135” (3.43 mm) RECOMMENDED ASSEMBLY: 4 CONDUCTORS CABLED WITH FILLERS IN A 4.25” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING BRAID: 34 AWG TINNED COPPER, 85% COVERAGE • ROBOTICS AND PLANT AUTOMATION EQUIPMENT SEPARATOR: OVERALL PAPER TAPE, 25% OVERLAP • MATERIAL HANDLING EQUIPMENT JACKET: ORANGE THERMOPLASTIC ELASTOMER • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE NOMINAL WALL: .065" (1.65 mm) TRAYS - EXPOSED RUNS NOMINAL OD: .506” (12.85 mm) LISTINGS/ UL TYPE TC-ER - 90°C, 600V CONDUCTOR COLOR CODE CE - LOW VOLTAGE DIRECTIVE CONDUCTOR #1-#3: BLACK W/ NUMBER PRINTING ELECTRICAL CHARACTERISTICS CONDUCTOR DCR: .54 Ω/100m (1.64 Ω/Mft) MAX PRINT LEGEND: MOHAWK E163873 M58807 12 AWG (3.29 mm sq) 4 COND SHIELDED - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40201 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A UPDATE HEADER, APPLICATIONS, PRINT 07/20/07 BA B CHG RECOMMENDED TEMP RANGE TO 90°C 08/03/07 BA Date: 05/30/07 Page 1 of 1 Part Number: M58807 Orig: Review: SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +105°C CABLE APPLICATIONS • MATERIAL HANDLING EQUIPMENT NOMINAL OD: .474” (12.0 mm) Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. SPECIFICATION 4 CONDUCTOR HEAVY DUTY FLEXIBLE POWER SUPPLY CABLE K40171 12 AWG / 4C Jacket Insulation Conductor Barrier CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 12 AWG (3.29 mm2) (65/30) BARE COPPER CABLE WEIGHT: 189 lbs/1000ft (281 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.8” (96 mm) MIN (8 x CABLE OD) NOMINAL DIAMETER: .135” (3.43 mm) RECOMMENDED ASSEMBLY: 4 CONDUCTORS CABLED WITH FILLERS IN A 4.25” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT JACKET: ORANGE THERMOPLASTIC ELASTOMER • MACHINE TOOLS RATINGS/ UL TYPE TC-ER - 90°C, 600V CONDUCTOR COLOR CODE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR #1-#3: BLACK W/WHITE NUMBER PRINTING CE / LOW VOLTAGE DIRECTIVE CONDUCTOR #4: GREEN W/YELLOW STRIPE ELECTRICAL CHARACTERISTICS CONDUCTOR DCR: .54 Ω/100m (1.64 Ω/Mft) MAX PRINT LEGEND: MOHAWK E163873 M58071 - UL 1277 TC-ER - 600V THHN (UL) 12 AWG (3.29 mm sq) 4 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40171 CE MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. D DELETE SEQ FOOTAGE MARKS & DATE CODE 12/10/03 JS E UPDATE HEADER/FOOTER, LISTINGS, PRINT 02/03/05 JS F CHANGE CSA RATING FROM 105C TO 90C 06/14/05 VB G CHANGE DIA, WT, MBR, PRINT 07/11/05 RA Date: 03/29/01 Page 1 of 1 Part Number: M58071 Orig: Review: SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .550” (13.97 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR DCR: .54 Ω/100m (1.64 Ω/Mft) MAX Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 7 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40152 12 AWG / 7C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: 12 AWG (3.29 mm2) (65/30) BARE COPPER CABLE WEIGHT: 244 lbs/1000ft (363 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 5.5” (139 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .135” (3.43 mm) RECOMMENDED ASSEMBLY: 7 CONDUCTORS CABLED TOGETHER WITH WITH A LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: BLACK FLAME RETARDANT TPE • ROBOTICS AND PLANT AUTOMATION EQUIPMENT RATINGS/ UL TYPE TC - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#6: BLACK W/WHITE NUMBER PRINTING CONDUCTOR #7: GREEN W/YELLOW STRIPE PRINT LEGEND: MOHAWK E163873 M57863 - UL 1277 TC-ER - 600V TFFN (UL) 12 AWG (3.29 mm sq) 7 COND SUN RES --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40152 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. D UPDATE FORMAT; ADD FILE #'s & UL 1277 TO PRINT 04/11/01 JS E ADD MM SQ; UPDATE TO TC-ER PRINT; CHG TEMP 06/23/04 JS F CHANGE HEADER & FOOTER, MODIFICATIONS 02/13/07 VB G UPD HDR, TEMPS, APPS, PRINT; ADD ROHS 05/14/08 JS Date: 03/07/00 Page 1 of 1 Part Number: M57863 Orig: Review: 14 AWG Cable Specifications SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .360” (9.14 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR #3: GREEN W/YELLOW STRIPE Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 3 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40227 14 AWG / 3C Jacket Insulation Conductor Barrier Filler CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 14 AWG (2.08 mm²) (41/30) BARE COPPER CABLE WEIGHT: 86 lbs/1000ft (128 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.6” (91 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .114” (2.9 mm) RECOMMENDED ASSEMBLY: 3 CONDUCTORS CABLED TOGETHER IN A 3.25” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT LISTINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE - LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1: ORANGE CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX CONDUCTOR #2: WHITE W/ORANGE STRIPE PRINT LEGEND: MOHAWK E163869 M58835 14 AWG (2.08 mm sq) 3 COND - UL 1277 TC-ER - 600V THHN --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40227 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A UPDATE PRINT; ADD PART NUMBER 04/28/08 JS Date: 04/03/08 Page 1 of 1 Part Number: M58835 Orig: Review: SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .360” (9.14 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR #3: GREEN W/YELLOW STRIPE Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 3 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40212 14 AWG / 3C Jacket Insulation Conductor Barrier Filler CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 14 AWG (2.08 mm²) (41/30) BARE COPPER CABLE WEIGHT: 86 lbs/1000ft (128 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.6” (91 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .114” (2.9 mm) RECOMMENDED ASSEMBLY: 3 CONDUCTORS CABLED TOGETHER IN A 3.25” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT LISTINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE - LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS ELECTRICAL CHARACTERISTICS CONDUCTOR COLOR CODE CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX CONDUCTOR #1-#2: YELLOW W/BLACK NUMBER PRINTING PRINT LEGEND: MOHAWK E163869 M58750 14 AWG (2.08 mm sq) 3 COND - UL 1277 TC-ER - 600V THHN --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40212 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. C ADDED ROHS INFORMATION 06/27/07 VB D CHANGED CSA TEMP TO 90°C 07/11/07 VB E UPDATE HDR, BEND RADIUS, APPLICATIONS 07/10/07 BA F PERM. CHG FROM PUR/AWM TO TPE/TC-ER 04/08/08 JS Date: 01/11/05 Page 1 of 1 Part Number: M58750 Orig: Review: BENDING RADIUS: 4.3" (109 mm) MIN (10 x CABLE OD) INSULATION: .016” (.41 mm) OF 105°C PVC 3.5” LEFT HAND LAY • ROBOTICS AND PLANT AUTOMATION EQUIPMENT 25% OVERLAP ORANGE THERMOPLASTIC ELASTOMER JACKET: • MATERIAL HANDLING EQUIPMENT ELECTRICAL CHARACTERISTICS Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 4 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40157 14 AWG / 4C Jacket Insulation Conductor Barrier CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 14 AWG (2.08 mm2) (41/30) BARE COPPER CABLE WEIGHT: 126 lbs/1000ft (188 kg/km) SHEATH: .005” (.13 mm) OF NYLON RECOMMENDED NOMINAL DIAMETER: .114” (2.9 mm) TEMP. RANGE: -25°C TO +90°C CABLE ASSEMBLY: 4 CONDUCTORS CABLED TOGETHER IN A APPLICATIONS BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING • MACHINE TOOLS NOMINAL OD: .426” (10.82 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS/ UL TYPE TC-ER - 90°C, 600V TRAYS - EXPOSED RUNS RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CE / LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDUCTOR #1-#3: BLACK W/ NUMBER PRINTING CONDUCTOR #4: GREEN W/YELLOW STRIPE CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX PRINT LEGEND: MOHAWK E163873 M58002 14 AWG (2.08 mm sq) 4 COND - UL 1277 TC-ER - 600V THHN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40157 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. K CHANGED MIN BENDING RADIUS TO 10 X DIA 06/04/07 VB L ADD SEQ FT MARKS & DATE CODE 06/06/07 JS M UPD HDR, BEND RAD, APPS, PRINT; ADD ROHS 07/20/07 BA N CHG RECOMMENDED TEMP RANGE TO 90°C 08/03/07 BA Date: 09/14/00 Page 1 of 1 Part Number: M58002 Orig: Review: BENDING RADIUS: 4.0” (101 mm) MIN (10 x CABLE OD) INSULATION: .016” (.41 mm) OF 105°C PVC 3.5” LEFT HAND LAY • ROBOTICS AND PLANT AUTOMATION EQUIPMENT 25% OVERLAP GRAY THERMOPLASTIC ELASTOMER JACKET: • MATERIAL HANDLING EQUIPMENT ELECTRICAL CHARACTERISTICS Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 4 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40093 14 AWG / 4C Jacket Insulation Conductor Barrier CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 14 AWG (2.08 mm2) (41/30) BARE COPPER CABLE WEIGHT: 115 lbs/1000ft (171 kg/km) SHEATH: .005” (.13 mm) OF NYLON RECOMMENDED NOMINAL DIAMETER: .114” (2.9 mm) TEMP. RANGE: -25°C TO + 90°C CABLE ASSEMBLY: 4 CONDUCTORS CABLED TOGETHER IN A APPLICATIONS BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING • MACHINE TOOLS NOMINAL OD: .399” (10.13 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS/ UL TYPE TC-ER - 90°C, 600V TRAYS - EXPOSED RUNS LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CE / LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDUCTOR #1-#3: BLACK W/WHITE NUMBER PRINTING CONDUCTOR #4: GREEN W/YELLOW STRIPE CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX PRINT LEGEND: MOHAWK E163873 M58829 - UL 1277 TC-ER - 600V THHN (UL) 14 AWG (2.08 mm sq) 4 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40093 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A CHANGE PRINT, HEADER & FOOTER 09/28/06 VB B CHG TEMP RATINGS, CHG PRINT, ADDED ROHS 11/13/07 VB C ADD P/N & K # 03/26/08 JS Date: 01/22/04 Page 1 of 1 Part Number: M58829 Orig: Review: INSULATION: .016” (.41 mm) OF 105°C PVC TEMP. RANGE: -25°C TO +90°C NOMINAL DIAMETER: .114” (2.9 mm) APPLICATIONS 4.0” LEFT HAND LAY 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT TRAYS - EXPOSED RUNS LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V ELECTRICAL CHARACTERISTICS CONDUCTOR #5: GREEN W/YELLOW STRIPE Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 5 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40096 14 AWG / 5C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 14 AWG (2.08 mm²) (41/30) BARE CABLE WEIGHT: 136 lbs/1000ft (201 kg/km) COPPER BENDING RADIUS: 4.3” (109 mm) MIN (10 x CABLE OD) SHEATH: .005” (.13 mm) OF NYLON RECOMMENDED CABLE ASSEMBLY: 5 CONDUCTORS CABLED TOGETHER IN A BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • MACHINE TOOLS NOMINAL OD: .432” (10.97 mm) • MATERIAL HANDLING EQUIPMENT RATINGS/ UL TYPE TC-ER - 90°C, 600V • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE CE / LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDUCTOR #1-#4: DK. BLUE W/WHITE NUMBER PRINTING CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX PRINT LEGEND: MOHAWK E163873 M58830 - UL 1277 TC-ER - 600V THHN (UL) 14 AWG (2.08 mm sq) 5 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40096 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A CHANGE HEADER, FOOTER & PRINT 09/28/06 VB B CHG TEMP RATINGS, CHG PRINT, ADDED ROHS 11/13/07 VB C ADD P/N & K # 03/26/08 JS Date: 01/22/04 Page 1 of 1 Part Number: M58830 Orig: Review: BENDING RADIUS: 5.0” (127 mm) MIN (10 x CABLE OD) SHEATH: .005” (.13 mm) OF NYLON 25% OVERLAP ORANGE THERMOPLASTIC ELASTOMER JACKET: • ROBOTICS AND PLANT AUTOMATION EQUIPMENT • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V ELECTRICAL CHARACTERISTICS Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 7 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40129 14 AWG / 7C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 14 AWG (2.08 mm²) (41/30) BARE COPPER CABLE WEIGHT: 178 lbs/1000ft (265 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC NOMINAL DIAMETER: .114” (2.9 mm) RECOMMENDED CABLE 7 CONDUCTORS CABLED TOGETHER IN A TEMP. RANGE: -25°C TO +90°C ASSEMBLY: 4.50” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, APPLICATIONS • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING NOMINAL OD: .495” (12.57 mm) • MACHINE TOOLS RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE CONDUCTOR #1-#6: BLACK W/WHITE NUMBER PRINTING CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX CONDUCTOR #7: GREEN W/YELLOW STRIPE PRINT LEGEND: MOHAWK E163873 M58942 - UL 1277 TC-ER - 600V THHN (UL) 14 AWG (2.08 mm sq) 7 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40129 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADJUST JKT DIA, CABLE WGT, BEND RADIUS 12/10/09 JS B UPDATE PRINT WITH M # AND K # 12/11/09 JS Date: 12/07/09 Page 1 of 1 Part Number: - Orig: Review: 16 AWG Cable Specifications SHEATH: .0045” (.11 mm) OF NYLON TEMP. RANGE: -25°C TO + 90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .337” (8.56 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR #3: GREEN W/YELLOW STRIPE Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 3 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40240 16 AWG / 3C Jacket Insulation Conductor Barrier Filler CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 73 lbs/1000ft (108 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.3” (84 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .101” (2.57 mm) RECOMMENDED ASSEMBLY: 3 CONDUCTORS CABLED WITH FILLERS IN A 2.75” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#2: ORANGE W/BLACK NUMBER PRINTING CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX PRINT LEGEND: MOHAWK E163873 M 16 AWG (1.31 mm sq) 3 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A MODIFY PRINT 10/12/09 JS Date: 03/11/08 Page 1 of 1 Part Number: - Orig: Review: SHEATH: .0045” (.11 mm) OF NYLON TEMP. RANGE: -30°C TO +105°C CABLE APPLICATIONS • MATERIAL HANDLING EQUIPMENT NOMINAL OD: .337” (8.56 mm) CONDUCTOR COLOR CODE LISTINGS: CSA AWM I/II A/B FT4 - 105°C, 600V Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 3 CONDUCTOR HEAVY DUTY FLEXIBLE POWER SUPPLY CABLE K40127 16 AWG / 3C Jacket Insulation Conductor Barrier Filler CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 73 lbs/1000ft (108 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 2.7” (68 mm) MIN (8 x CABLE OD) NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED ASSEMBLY: 3 CONDUCTORS CABLED WITH FILLERS IN A 2.75” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT JACKET: GRAY THERMOPLASTIC ELASTOMER • MACHINE TOOLS RATINGS/ UL TYPE TC-ER - 90°C, 600V CE / LOW VOLTAGE DIRECTIVE CONDUCTOR #1-#2: YELLOW W/BLACK NUMBER PRINTING CONDUCTOR #3: GREEN W/YELLOW STRIPE ELECTRICAL CHARACTERISTICS CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX PRINT LEGEND: MOHAWK E83542 M58792 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 3 COND --- LL34280 CSA AWM I/II A/B 105C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40127 CE MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADD P/N & ROHS; UPDATE LISTINGS, PRINT 04/27/07 JS Date: 01/22/04 Page 1 of 1 Part Number: M58792 Orig: Review: SHEATH: .0045” (.11 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .363” (9.22 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 4 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40159 16 AWG / 4C Jacket Insulation Conductor Barrier CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 90 lbs/1000ft (134 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.6” (91 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED ASSEMBLY: 4 CONDUCTORS CABLED WITH FILLERS IN A 3.0” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#3: BLUE W/WHITE NUMBER PRINTING CONDUCTOR #4: GREEN W/YELLOW STRIPE PRINT LEGEND: MOHAWK E163873 M58793 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 4 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40159 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADD P/N & ROHS; UPDATE LISTINGS, PRINT, WGT 04/27/07 JS B CHG FILE # ON PRINT, TEMP RATING, CHG HEADER 07/25/07 VB C CHG RECOMMENDED TEMP RANGE TO 90°C 08/01/07 VB Date: 01/22/04 Page 1 of 1 Part Number: M58793 Orig: Review: SHEATH: .0045” (.11 mm) OF NYLON TEMP. RANGE: -30°C TO +105°C CABLE APPLICATIONS • MATERIAL HANDLING EQUIPMENT CONDUCTOR COLOR CODE RATINGS/ UL TYPE TC-ER - 90°C, 600V Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 4 CONDUCTOR HEAVY DUTY FLEXIBLE POWER SUPPLY CABLE K40221 16 AWG / 4C Jacket Insulation Conductor Barrier Braid CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 104 lbs/1000ft (155 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.9” (99 mm) MIN (8 x CABLE OD) NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED ASSEMBLY: 4 CONDUCTORS CABLED TOGETHER WITH FILLERS IN A 3.0" LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT BRAID: #36 AWG TINNED COPPER, 65% COVERAGE • MACHINE TOOLS JACKET: ORANGE THERMOPLASTIC ELASTOMER NOMINAL OD: .385” (9.78 mm) LISTINGS: CSA AWM I/II A/B FT4 - 105°C, 600V CONDUCTOR #1-#3: BLACK W/WHITE NUMBER PRINTING CE / LOW VOLTAGE DIRECTIVE CONDUCTOR #4: GREEN W/YELLOW STRIPE ELECTRICAL CHARACTERISTICS CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX PRINT LEGEND: MOHAWK E83542 M58796 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 4 COND --- LL34280 CSA AWM I/II A/B 105C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40221 CE MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A UPDATE PRINT; ADD PART NUMBER 05/08/07 JS Date: 05/02/07 Page 1 of 1 Part Number: M58796 Orig: Review: SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .445” (11.30 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR #7: GREEN W/YELLOW STRIPE Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 7 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40238 16 AWG / 7C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 129 lbs/1000ft (192 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.2” (107 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .101” (2.57 mm) RECOMMENDED ASSEMBLY: 7 CONDUCTORS CABLED TOGETHER WITH A LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#6: ORANGE W/BLACK NUMBER PRINTING CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX PRINT LEGEND: MOHAWK E163873 M 16 AWG (1.31 mm sq) 7 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A MODIFY PRINT 10/12/09 JS Date: 03/11/08 Page 1 of 1 Part Number: - Orig: Review: SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .444” (11.28 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR #7: GREEN W/YELLOW STRIPE Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 7 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40215 16 AWG / 7C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 129 lbs/1000ft (192 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.2” (107 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .100” (2.54 mm) RECOMMENDED ASSEMBLY: 7 CONDUCTORS CABLED TOGETHER WITH A LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#6: DK. BLUE W/WHITE NUMBER PRINTING CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX PRINT LEGEND: MOHAWK E163873 M58715 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 7 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40215 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A UPDATE PRINT; ADD K # & P/N 01/04/06 JS B REVISE PRINT 09/28/06 VB C CHG TEMP RATINGS, CHG PRINT, ADDED ROHS 11/13/07 VB D INCREASE OVERALL CABLE DIAMETER 01/11/08 VB Date: 08/24/05 Page 1 of 1 Part Number: M58715 Orig: Review: SHEATH: .0045” (.11 mm) OF NYLON TEMP. RANGE: -25°C TO +105°C CABLE APPLICATIONS • MATERIAL HANDLING EQUIPMENT NOMINAL OD: .418” (10.62 mm) CONDUCTOR COLOR CODE RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 7 CONDUCTOR HEAVY DUTY FLEXIBLE POWER SUPPLY CABLE K40181 16 AWG / 7C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 121 lbs/1000ft (180 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.2” (107 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED ASSEMBLY: 7 CONDUCTORS CABLED TOGETHER IN A 3.75” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT JACKET: GRAY THERMOPLASTIC ELASTOMER • MACHINE TOOLS LISTING/ UL TYPE TC-ER - 90°C, 600V CE - LOW VOLTAGE DIRECTIVE CONDUCTOR #1-#6: RED W/BLACK NUMBER PRINTING CONDUCTOR #7: GREEN W/YELLOW STRIPE ELECTRICAL CHARACTERISTICS CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX PRINT LEGEND: MOHAWK E163873 M58107 16 AWG (1.31 mm sq) 7 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40181 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & YEAR/SHOP ORDER CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. B UPDATE PRINT 01/04/05 JS C CHG PUR TO TPE, AWM TO TC-ER, ADDED ROHS 05/17/07 VB D CHANGED TEMP & FILE NOS. 05/24/07 VB E CHANGED DIA TO .418" AND MIN BEND RADIUS 06/04/07 VB Date: 05/16/01 Page 1 of 1 Part Number: M58107 Orig: Review: SHEATH: .0045” (.11 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .428” (10.87 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 7 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40208 16 AWG / 7C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 121 lbs/1000ft (180 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.3” (109 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED ASSEMBLY: 7 CONDUCTORS CABLED TOGETHER IN A 3.75” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT LISTINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE - LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#6: YELLOW W/BLACK NUMBER PRINTING CONDUCTOR #7: GREEN W/YELLOW STRIPE PRINT LEGEND: MOHAWK E163873 M58599 16 AWG (1.31 mm sq) 7 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40208 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. C UPDATE PRINT & TEMPERATURES 06/01/07 JS D CHANGED OVERALL DIA TO .428" O.D. 06/08/07 VB E UPDATE HDR, BEND RADIUS, APPS, DATE CODE 07/20/07 BA F CHG RECOMMENDED TEMP RANGE TO 90°C 08/03/07 BA Date: 10/26/04 Page 1 of 1 Part Number: M58599 Orig: Review: SHEATH: .0045” (.11 mm) OF NYLON TEMP. RANGE: -30°C TO +105°C CABLE APPLICATIONS • MATERIAL HANDLING EQUIPMENT NOMINAL OD: .550” (13.97 mm) CONDUCTOR COLOR CODE RATINGS: CSA AWM I/II A/B FT4 - 105C, 600V Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. SPECIFICATION 12 CONDUCTOR HEAVY DUTY FLEXIBLE POWER SUPPLY CABLE K40210 16 AWG / 12C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 215 lbs/1000ft (318 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.4” (111 mm) MIN (8 x CABLE OD) NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED ASSEMBLY: 12 CONDUCTORS CABLED TOGETHER IN A 5.25” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT JACKET: GRAY THERMOPLASTIC ELASTOMER • MACHINE TOOLS LISTING/ UL TYPE TC-ER - 90C, 600V CE - LOW VOLTAGE DIRECTIVE CONDUCTOR #1-#11: RED W/BLACK NUMBER PRINTING CONDUCTOR #12: GREEN W/YELLOW STRIPE ELECTRICAL CHARACTERISTICS CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX PRINT LEGEND: MOHAWK E83542 M58601 16 AWG (1.31 mm sq) 12 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL34280 CSA AWM I/II A/B 105C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40210 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & YEAR/SHOP ORDER CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADD PART NUMBER; UPDATE PRINT 01/04/05 JS B CHG PUR TO TPE, AWM TO TC-ER, ADDED ROHS 05/21/07 VB Date: 12/22/04 Page 1 of 1 Part Number: M58601 Orig: Review: SHEATH: .0045” (.11 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .535” (13.59 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS: CSA AWM I/II A/B FT4 - 90C, 600V ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#11: YELLOW W/BLACK NUMBER PRINTING Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 12 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40216 16 AWG / 12C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 199 lbs/1000ft (296 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 5.35” (136 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED ASSEMBLY: 12 CONDUCTORS CABLED TOGETHER IN A 5.25” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY FLAME RETARDANT TPE • ROBOTICS AND PLANT AUTOMATION EQUIPMENT LISTING/ UL TYPE TC-ER - 90C, 600V • MATERIAL HANDLING EQUIPMENT CE - LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX CONDUCTOR #12: GREEN W/YELLOW STRIPE PRINT LEGEND: MOHAWK E163873 M58716 16 AWG (1.31 mm sq) 12 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40216 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A UPDATE PRINT; ADD K # & P/N 01/04/06 JS B UPD HDR, PRINT, TEMPS, APPS, BEND; ADD ROHS 09/02/08 JS Date: 08/24/05 Page 1 of 1 Part Number: M58716 Orig: Review: SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .565” (14.35 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 12 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40052 16 AWG / 12C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 216 lbs/1000ft (321 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 5.5” (140 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .101” (2.56 mm) RECOMMENDED ASSEMBLY: 12 CONDUCTORS CABLED TOGETHER IN A 5.25” LEFT HAND LAY BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT LISTING/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE - LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#11: DK. BLUE W/WHITE NUMBER PRINTING CONDUCTOR #12: GREEN W/YELLOW STRIPE PRINT LEGEND: MOHAWK E163873 M56561 16 AWG (1.31 mm sq) 12 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40052 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & YEAR/SHOP ORDER CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. I UPDATE PRINT FOR mm sq & SQ FOOTAGE MARKS 05/08/02 JS J UPDATE HEADER/FOOTER, WGT, PRINT 06/08/05 JS K CHG PUR TO TPE, AWM TO TC-ER, ADJ DIA/WGT 08/20/07 VB L ADJ COND NOM DIA, ADJ FINAL OD 08/28/07 VB Date: 07/17/95 Page 1 of 1 Part Number: M56561 Orig: Review: GENERAL PRODUCT SPECIFICATION Phone 800-316-8877 Fax 978-368-1275 www.jamesmonroewire.com Description: Eighteen Conductor, 16 AWG, Tray Cable-ER PP Foam Tape and Overall TPE Jacket Date: 9/2/2008 Cable Diagram Jacket Binder Insulated Conductor Components Eighteen 16 AWG Insulated Conductors Conductor: 16 AWG, 65/34 bare copper Insulation: .016" nominal wall of PVC (See Color Code) Nylon Jacket: .005" nominal wall of Clear Nylon .100" Cable Construction Cabling: Eighteen conductors cabled together around solid PVC filler with contra-helical lays Binder: Foam Propylene tape Jacket: .072" nominal wall of Gray TPE .657" (.690" max) Print JMWCC E73202 18/C 16 AWG (1.31 mm 2) TC-ER 90C DRY 75C WET 600V (UL) - - - LL41103 CSA AWM I/II A/B 90C 600V FT4 - - - ELECTRIVERT FLEX-LINK SERIES K40233 CE (with Sequential Footage Marks every 2 feet) Color Code Conductors 1 thru 17: Conductor 18: Yellow and numerically printed Green/Yellow ground Requirements Temperature: 90°C Voltage: 600V Approvals: UL Type TC-ER CSA AWM, I/II, A/B CE - LVD RoHS Compliant File:Public\JMWC_Ref\Spec\JMEVT40233-18C16-65str-TPE-TC.xls Written By: RA 9/2/2008 Rev. 0 Initial Issue Revised By: Revised By: Revised By: K40233 16 AWG / 18C SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING NOMINAL OD: .690” (17.53 mm) MACHINE TOOLS ELECTRICAL CHARACTERISTICS Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 19 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40014 16 AWG / 19C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 355 lbs/1000ft (528 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 6.9” (175 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .101” (2.56 mm) RECOMMENDED CABLE 19 CONDUCTORS AND FILLERS CABLED ASSEMBLY: TOGETHER WITH CONTRA-HELICAL LAYS BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, APPLICATIONS 25% OVERLAP JACKET: GRAY THERMOPLASTIC ELASTOMER ROBOTICS AND PLANT AUTOMATION EQUIPMENT RATINGS/ UL TYPE TC-ER - 90°C, 600V MATERIAL HANDLING EQUIPMENT LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V TC-ER COMPLIANT FOR CABLES EXTENDED FROM CE / LOW VOLTAGE DIRECTIVE CABLE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE CONDUCTOR #1-#18: DK. BLUE W/WHITE NUMBER PRINTING CONDUCTOR DCR: 1.46 /100m (4.44 /Mft) MAX CONDUCTOR #19: GREEN W/YELLOW STRIPE PRINT LEGEND: MOHAWK E163873 M 16 AWG (1.31 mm sq) 19 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADJUST DIAMETER, CABLE WGT, BEND RADIUS 01/07/10 JS Date: 01/04/10 Page 1 of 1 Part Number: - Orig: Review: SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .793” (20.14 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 25 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE K40049 16 AWG / 25C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 438 lbs/1000ft (652 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 7.9” (201 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .101” (2.56 mm) RECOMMENDED ASSEMBLY: 25 CONDUCTORS AND FILLERS CABLED TOGETHER WITH CONTRA-HELICAL LAYS BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#24: DK. BLUE W/WHITE NUMBER PRINTING CONDUCTOR #25: GREEN W/YELLOW STRIPE PRINT LEGEND: MOHAWK E163873 M56678 16 AWG (1.31 mm sq) 25 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40049 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. K ADJUST DIAMETER & WEIGHT; ADD ROHS 05/02/07 JS L CHG TEMPS, BEND RADIUS, PRINT LEGEND 08/20/07 VB M ADJ COND NOM OD, ADJ FINAL CABLE OD 08/28/07 VB N ADJUST BEND RADIUS 09/04/07 JS Date: 01/15/96 Page 1 of 1 Part Number: M56678 Orig: Review: GENERAL PRODUCT SPECIFICATION Phone 800-316-8877 Fax 978-368-1275 www.jamesmonroewire.com Description: Twenty-Five Conductor, 16 AWG, Tray Cable-ER PP Foam Tape and Overall TPE Jacket Date: 9/2/2008 Cable Diagram Jacket Binder Insulated Conductor Components Twenty-Five 16 AWG Insulated Conductors Conductor: 16 AWG, 65/34 bare copper Insulation: .016" nominal wall of PVC (See Color Code) Nylon Jacket: .005" nominal wall of Clear Nylon .100" Cable Construction Cabling: Twenty-five conductors cabled together around solid PVC filler with contra-helical lays Binder: Foam Propylene tape Jacket: .083" nominal wall of Gray TPE .794" (.834" max) Print JMWCC E73202 25/C 16 AWG (1.31 mm 2) TC-ER 90C DRY 75C WET 600V (UL) - - - LL41103 CSA AWM I/II A/B 90C 600V FT4 - - - ELECTRIVERT FLEX-LINK SERIES K40234 CE (with Sequential Footage Marks every 2 feet) Color Code Conductors 1 thru 24: Conductor 25: Yellow and numerically printed Green/Yellow ground Requirements Temperature: 90°C Voltage: 600V Approvals: UL Type TC-ER CSA AWM, I/II, A/B CE - LVD RoHS Compliant File:Public\JMWC_Ref\Spec\JMEVT40234-25C16-65str-TPE-TC.xls Written By: RA 9/2/2008 Rev. 0 Initial Issue Revised By: Revised By: Revised By: K40234 16 AWG / 25C SHEATH: .005” (.13 mm) OF NYLON TEMP. RANGE: -25°C TO +90°C CABLE APPLICATIONS • MACHINE TOOLS NOMINAL OD: .865” (21.97 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V GROUND CONDUCTOR: GREEN W/YELLOW STRIPE Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 33 CONDUCTOR HEAVY DUTY FLEXIBLE POWER SUPPLY CABLE K40218 16 AWG / 33C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm²) (65/34) BARE COPPER CABLE WEIGHT: 550 lbs/1000ft (818 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 8.6” (218 mm) MIN (10 x CABLE OD) NOMINAL DIAMETER: .101” (2.57 mm) RECOMMENDED ASSEMBLY: 33 CONDUCTORS AND A FILLER CABLED TOGETHER WITH CONTRA-HELICAL LAYS BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY FLAME RETARDANT TPE • ROBOTICS AND PLANT AUTOMATION EQUIPMENT RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#32: DK. BLUE W/WHITE NUMBER PRINTING CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX PRINT LEGEND: MOHAWK E83542 M58766 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 33 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40218 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A CHANGE JACKET COLOR TO LIGHT GRAY 09/06/06 VB B ADD PART NUMBER; UPDATE PRINT & WEIGHT 09/11/06 JS C ADJ TEMPS, BEND RAD, PRINT, APPS; ADD ROHS 03/27/08 JS D ADJUST DIAMETERS, WGT, BEND RADIUS 03/28/08 JS Date: 03/07/05 Page 1 of 1 Part Number: M58766 Orig: Review: POWER SUPPLY CABLE NOMINAL DIAMETER: .099” (2.51 mm) ASSEMBLY: 37 CONDUCTORS CABLED TOGETHER IN TEMP. RANGE: -25°C TO +90°C • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING • MACHINE TOOLS • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE NOMINAL OD: .925” (23.49 mm) Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 37 CONDUCTOR SHIELDED HEAVY DUTY K40204 16 AWG / 37C JACKET BRAID DRAIN INSULATION CONDUCTOR BARRIER CONSTRUCTION ELECTRICAL CHARACTERISTICS PRIMARIES: CONDUCTOR: 16 AWG (1.31 mm²) CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX (65 STRANDS OF 34 AWG) BARE COPPER INSULATION: .016” (.41 mm) OF 105°C PVC SHEATH: .0045” (.11 mm) OF NYLON PHYSICAL CHARACTERISTICS CABLE WEIGHT: 637 lbs/1000ft (948 kg/km) CABLE BENDING RADIUS: 9.25” (235 mm) MIN (10 x CABLE OD) CONTRA-HELICAL LAYS RECOMMENDED BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP APPLICATIONS DRAIN WIRE: 18 AWG (16/30) TINNED COPPER BRAID SHIELD: 34 AWG TINNED COPPER, 70% COVERAGE • NOT FOR CONTINUOUS FLEXING JACKET: BLACK FLAME RETARDANT TPE • MATERIAL HANDLING EQUIPMENT TRAYS - EXPOSED RUNS RATINGS/ UL TYPE TC-ER - 90°C, 600V LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CE / LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDS #1 - #36: BLACK W/WHITE NUMBER PRINTING GROUND COND: GREEN W/YELLOW STRIPE LEGEND: MOHAWK E163873 M58488 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 37 COND SUN RES --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40204 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. C UPDATE TITLE, COND, ADD APPS 05/21/07 RA D CHG TEMPS, PRINT LEGEND, ADDED ROHS 11/29/07 VB E MODIFIED ONE OF THE APPLICATIONS 12/05/07 VB F CHANGE FINAL OD 12/10/07 VB Date: 03/01/04 Page 1 of 1 Part Number: M58488 Orig: Review: 22 AWG Cable Specifications NOMINAL DIAMETER: .050” (1.27 mm) TEMP. RANGE: -20°C TO +105°C ASSEMBLY: 24 CONDUCTORS CABLED TOGETHER AROUND A CONDUCTOR COLOR CODE CONDUCTOR #24: GREEN W/YELLOW STRIPE RATINGS: NON-CSA Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 24 CONDUCTOR 22 AWG CABLE POWER SUPPLY K40182 22 AWG / 24C JACKET CONDUCTOR INSULATION BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 22 AWG (.35 mm2) (7/30) TINNED COPPER CABLE WEIGHT: 108 lbs/1000ft (161 kg/km) INSULATION: .010” (.25 mm) OF 80°C PVC BENDING RADIUS: 4.2” (107 mm) MIN (10 x CABLE OD) CABLE RECOMMENDED FILLER IN A LEFT HAND LAY BARRIER: OVERALL PAPER TAPE, 25% OVERLAP JACKET: GRAY THERMOPLASTIC ELASTOMER NOMINAL OD: .415” (10.54 mm) LISTING/ UL TYPE PLTC - 80C CONDUCTOR #1-#23: DK. BLUE W/WHITE NUMBER PRINTING CE - LOW VOLTAGE DIRECTIVE ELECTRICAL CHARACTERISTICS CONDUCTOR DCR: 5.74 Ω/100m (17.5 Ω/Mft) MAX PRINT LEGEND: MOHAWK E M58122 22 AWG (.35 mm sq) 24 COND (UL) TYPE PLTC 80C --- --- K40182 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. B CHG PRINTTO INCLUDE mm sq, SFM, DATE CODE 10/09/02 JS C UPDATE HDR/FTR, PRINT 12/15/05 JS D CHG TEMPS, BEND RADIUS, ADDED ROHS 11/15/07 VB E CHG FINAL OD, NO CSA LISTING 12/5/07 VB Date: 06/06/01 Page 1 of 1 Part Number: M58122 Orig: Review: Communication / Shielded Cable Specifications RATINGS: CSA AWM I/II A/B FT4 - 80°C, 300V SHEATH: .003" (.076 mm) OF NYLON ELECTRICAL CHARACTERISTICS Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 3 COND 20 AWG SHIELDED CABLE K40228 20 AWG / 3C Jacket Braid Shield Conductor Drain Wire Shield Tape CONSTRUCTION PRIMARIES: COND: 20 AWG (.52 mm2) (19/32) TINNED COPPER LISTING/ UL PLTC-ER 105°C, 300V INSULATION: .010” (.25 mm) OF PVC CE - LOW VOLTAGE DIRECTIVE NOMINAL DIAMETER: .065” (1.65 mm) COLORS: BLACK, RED, WHITE CABLE CONDUCTOR DCR: 9.3 Ω/100m (28.3 Ω/Mft) MAX ASSEMBLY: 3 CONDUCTORS CABLED TOGETHER IN A 2.25" LEFT HAND LAY SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, 25% OVERLAP, 100% COVERAGE, ALUM SIDE OUT DRAIN WIRE: 22 AWG (19/34) TINNED COPPER BRAID: #36 AWG TINNED COPPER, 80% COV JACKET: MATERIAL: THERMOPLASTIC ELASTOMER WALL THICKNESS: .045" (1.14 mm) NOMINAL OD: .255” +/- .025" (6.48 mm +/- .63 mm) COLOR: GRAY PRINT LEGEND: MOHAWK E M58837 20 AWG (0.52 mm sq) 3 COND (UL) TYPE PLTC-ER SUN RES 105C --- LL CSA AWM I/II A/B 80C 300V FT4 --- ELECTRIFLEX K40228 CE (W/SEQUENTIAL FOOTAGE MARKS & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADDED CSA LISTING 02/22/08 VB B REVISE PRINT; ADD PART NUMBER 05/02/08 JS C REVISE PRINT; ADD K # 05/09/08 JS Date: 09/26/07 Page 1 of 1 Part Number: M58837 Orig: Review: Conductor RATINGS: CSA AWM I/II A/B FT4 - 80°C, 300V SHEATH: .003" (.076 mm) OF NYLON 4.0" LEFT HAND LAY Cabling Excellence for Open Architecture M. ohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 2 PAIR 20 AWG SHIELDED CABLE K40229 20 AWG / 2 PR Jacket Braid Shield Filler Drain Wire Shield Tape CONSTRUCTION PRIMARIES: COND: 20 AWG (.52 mm2) (19/32) TINNED COPPER LISTING/ UL PLTC-ER 105°C, 300V INSULATION: .010” (.25 mm) OF PVC CE - LOW VOLTAGE DIRECTIVE NOMINAL DIAMETER: .065” (1.65 mm) PAIR PAIR COLOR CODE ASSEMBLY: 2 PRIMARIES TWISTED IN A 2.0" LEFT HAND LAY PAIR #1: RED & BLACK PAIR #2: WHITE & BLACK CABLE ASSEMBLY: 2 PAIRS CABLED WITH FILLERS TOGETHER IN A ELECTRICAL CHARACTERISTICS CONDUCTOR DCR: 9.3 Ω/100m (28.3 Ω/Mft) MAX SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, 25% OVERLAP, 100% COVERAGE, ALUM SIDE OUT DRAIN WIRE: 22 AWG (19/34) TINNED COPPER BRAID: #36 AWG TINNED COPPER, 80% COV JACKET: MATERIAL: THERMOPLASTIC ELASTOMER WALL THICKNESS: .050" (1.27 mm) NOMINAL OD: .325” +/- .025" (8.25 +/- .63 mm) COLOR: GRAY PRINT LEGEND: MOHAWK E M58838 20 AWG (0.52 mm sq) 2PR (UL) TYPE PLTC-ER SUN RES 105C --- LL CSA AWM I/II A/B 80C 300V FT4 --- ELECTRIFLEX K40229 CE (W/SEQUENTIAL FOOTAGE MARKS & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADDED CSA LISTING 02/22/08 VB B REVISE PRINT; ADD PART NUMBER 05/02/08 JS C REVISE PRINT; ADD K # 05/09/08 JS Date: 09/26/07 Page 1 of 1 Part Number: M58838 Orig: Review: RATINGS: CSA AWM I/II A/B FT4 - 80°C, 300V Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 3 PAIR 20 AWG SHIELDED CABLE K40231 20 AWG / 3 PR Jacket Braid Shield Conductor Drain Wire Shield Tape CONSTRUCTION LISTING/ UL PLTC-ER 105°C, 300V PRIMARIES: COND: 20 AWG (.52 mm2) (19/32) TINNED COPPER CE - LOW VOLTAGE DIRECTIVE INSULATION: .010” (.25 mm) OF PVC SHEATH: .003" (.076 mm) OF NYLON NOMINAL DIAMETER: .065” (1.65 mm) PAIR PAIR COLOR CODE ASSEMBLY: 2 PRIMARIES TWISTED IN A 2.0" LEFT HAND LAY PAIR #1: RED & BLACK PAIR #2: BLUE & BLACK CABLE PAIR #3: GREEN & BLACK ASSEMBLY: 3 PAIRS CABLED TOGETHER IN A 4.0" LEFT HAND LAY ELECTRICAL CHARACTERISTICS SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, 25% CONDUCTOR DCR: 9.3 Ω/100m (28.3 Ω/Mft) MAX OVERLAP, 100% COVERAGE, ALUM SIDE OUT DRAIN WIRE: 22 AWG (19/34) TINNED COPPER BRAID: #36 AWG TINNED COPPER, 80% COV JACKET: MATERIAL: THERMOPLASTIC ELASTOMER WALL THICKNESS: .050" (1.27 mm) NOMINAL OD: .340” +/- .025" (8.64 +/- .63 mm) COLOR: GRAY PRINT LEGEND: MOHAWK E M58840 20 AWG (0.52 mm sq) 3PR (UL) TYPE PLTC-ER SUN RES 105C --- LL CSA AWM I/II A/B 80C 300V FT4 --- ELECTRIFLEX K40231 CE (W/SEQUENTIAL FOOTAGE MARKS & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A REVISE PRINT; ADD PART NUMBER 05/02/08 JS B REVISE PRINT; ADD K # 05/09/08 JS Date: 02/26/08 Page 1 of 1 Part Number: M58840 Orig: Review: GENERAL PRODUCT SPECIFICATION Phone 800-316-8877 Fax 978-368-1275 www.jamesmonroewire.com Description: Sixteen 20 AWG Twisted Pairs, Overall Foil Shield, Braid Shield and TPE Jacket Date: 8/29/2008 Jac ket Braid Shield Drain Wire Foil Shield Twisted Pair Components Conductors: Insulation: 20 AWG, 10/30 bare copper .016" nominal wall of PVC (see color code) .069" Pair Twist: Two 20 AWG insulated conductors twisted together .138" (major axis) Cable Construction Cabling: Sixteen twisted pairs cable together Foil Shield: Mylar-Aluminum tape, Aluminum side Out Drain Wire: 22 AWG, 7/30 tinned copper Braid Shield: 36 AWG tinned copper braid, 85% coverage Jacket: .065" nominal wall of Gray TPE .686" (.720" max) Print JMWCC E67179 16/PR 20 AWG (0.50 mm 2) 105C (UL) TYPE PLTC - - - LL41103 CSA AWM I/II A/B 105C 300V FT4 - - - ELECTRIVERT K40232 (with Sequential Footage Marks every 2 feet) CE Color Code 1. 2. 3. 4. 5. 6. Black and Red Black and White Black and Green Black and Blue Black and Yellow Black and Brown 7. 8. 9. 10. 11. 12. Black and Orange Red and White Red and Green Red and Blue Red and Yellow Red and Brown 13. 14. 15. 16. Red and Orange Green and White Green and Blue Green and Yellow Requirements Temperature: 105C Approvals: UL PLTC CSA AWM CE - Low Voltage Directive RoHS Compliant Voltage: 300V 1 of 1 File: public\\JMEVT40232-16PR20-10str-OS-OBS-PLTC-CSA-AWM.xls Written By: RA 8/29/2008 Rev. 0 Initial Issue Revised By: Revised By: Revised By: K40232 20 AWG / 16 PR P3 NOMINAL DIAMETER: .059” (1.50 mm) PAIR TEMP. RANGE: -50°C TO +80°C IN A 3.25” LEFT HAND LAY SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, PAIR #2: GREEN & YELLOW ALUMINUM SIDE FACING OUT AGAINST BRAID MAXIMUM OD: .335” (8.51 mm) Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. SPECIFICATION 3 PAIR 22 AWG SHIELDED CABLE K40161 22 AWG / 3 PR Jacket Braid Shield Insulation P2 Conductor Shield Tape PVC Filler P1 CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 22 AWG (0.33 mm²) (41/38) BARE COPPER CABLE WEIGHT: 57 lbs/1000ft (85 kg/km) INSULATION: .015” (.38 mm) OF POLYPROPYLENE BENDING RADIUS: 3.1” (79 mm) MIN (10 x CABLE OD) RECOMMENDED ASSEMBLY: 2 PRIMARIES TWISTED TOGETHER IN A 1.75” LEFT HAND LAY CABLE ASSEMBLY: 3 PAIRS CABLED TOGETHER WITH PVC FILLERS PAIR COLOR CODE PAIR #1: WHITE & BROWN 25% OVERLAP, 100% COVERAGE PAIR #3: GRAY & PINK BRAID: #36 AWG TINNED COPPER, 85% COV, 29° ANGLE JACKET: VIOLET POLYURETHANE ELECTRICAL CHARACTERISTICS NOMINAL OD: .310” (7.87 mm) CONDUCTOR DCR: 5.32 Ω/100m (16.21 Ω/Mft) MAX LISTING/ UL AWM STYLE 20233 - 80C, 300V RATINGS: CE - LOW VOLTAGE DIRECTIVE PRINT LEGEND: MOHAWK E28558 M58015 AWM STYLE 20233 80C 300V - 22 AWG (0.33 mm sq) 3 PRS --- ELECTRI-FLEX K40161 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & YEAR/SHOP ORDER CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A UPDATE FORMAT & PRINT 09/26/00 JL B ADD UL FILE # TO PRINT LEGEND & P/N 10/13/00 JL C ADD mm sq TO PRINT; ADD SEQ FOOTAGE MARKS 06/03/03 VB D UPDATE HEADER/FOOTER, PRINT 03/04/05 JS Date: 09/15/00 Page 1 of 1 Part Number: M58015 Orig: Review: P3 NOMINAL DIAMETER: .059” (1.50 mm) PAIR TEMP. RANGE: -50°C TO +80°C IN A 3.25” LEFT HAND LAY SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, PAIR #2: GREEN & YELLOW ALUMINUM SIDE FACING OUT AGAINST BRAID MAXIMUM OD: .335” (8.51 mm) Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. SPECIFICATION 3 PAIR 22 AWG SHIELDED CABLE K40160 22 AWG / 3 PR Jacket Braid Shield Insulation P2 Conductor Shield Tape PVC Filler P1 CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 22 AWG (0.33 mm2) (41/38) BARE COPPER CABLE WEIGHT: 57 lbs/1000ft (85 kg/km) INSULATION: .015” (.38 mm) OF POLYPROPYLENE BENDING RADIUS: 3.1” (79 mm) MIN (10 x CABLE OD) RECOMMENDED ASSEMBLY: 2 PRIMARIES TWISTED TOGETHER IN A 1.75” LEFT HAND LAY CABLE ASSEMBLY: 3 PAIRS CABLED TOGETHER WITH PVC FILLERS PAIR COLOR CODE PAIR #1: WHITE & BROWN 25% OVERLAP, 100% COVERAGE PAIR #3: GRAY & PINK BRAID: #36 AWG TINNED COPPER, 85% COV, 29° ANGLE JACKET: GRAY POLYURETHANE ELECTRICAL CHARACTERISTICS NOMINAL OD: .310” (7.87 mm) CONDUCTOR DCR: 5.32 Ω/100m (16.21 Ω/Mft) MAX LISTING/ UL AWM STYLE 20233 - 80C, 300V RATINGS: CE - LOW VOLTAGE DIRECTIVE PRINT LEGEND: MOHAWK E28558 M58014 AWM STYLE 20233 80C 300V - 22 AWG (0.33 mm sq) 3 PRS --- ELECTRI-FLEX K40160 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & YEAR/SHOP ORDER CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. B ADJUST K # 10/03/00 WL C ADD UL FILE # TO PRINT LEGEND & P/N 10/13/00 JL D ADD mm sq, SFM & DC TO PRINT 06/07/02 JS E UPDATE HEADER/FOOTER, PRINT 03/04/05 JS Date: 09/15/00 Page 1 of 1 Part Number: M58014 Orig: Review: CONDUCTOR: 22 AWG (.35 mm2) (7/30) PRIMARIES: NOMINAL DIAMETER: .050” ASSEMBLY: 2 PRIMARIES TWISTED IN A 1.5” LEFT HAND LAY P7 BLACK & ORANGE ASSEMBLY: 17 PAIRS CABLED WITH A 6” LEFT HAND LAY NOMINAL OD: .560" (14.22 mm) Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 17 PAIR SHIELDED CABLE K40036 22 AWG / 17 PR CONSTRUCTION COLOR CODE P1 BLACK & RED BARE COPPER P2 BLACK & WHITE INSULATION: .010” OF SEMI-RIGID PVC P3 BLACK & GREEN P4 BLACK & BLUE PAIR P5 BLACK & YELLOW P6 BLACK & BROWN CABLE (CORE: P1-P5, 1ST LAYER: P6-P17) P8 RED & WHITE BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, P9 RED & GREEN 25% OVERLAP P10 RED & BLUE DRAIN WIRE: 22 AWG (7/30) TINNED COPPER P11 RED & YELLOW BRAID SHIELD: 34 AWG TINNED COPPER, 44° ANGLE P12 RED & BROWN 91% COVERAGE P13 RED & ORANGE JACKET: COMPOUND: THERMOPLASTIC ELASTOMER P14 GREEN & WHITE NOMINAL WALL: .055" (1.40 mm) P15 GREEN & BLUE COLOR: BLACK P16 GREEN & YELLOW LISTING/ UL TYPE PLTC - 90C P17 GREEN & BROWN RATINGS: CSA - NONE LEGEND: MOHAWK E39829 M57325 22 AWG (.35 mm sq) 17PR (UL) TYPE PLTC 90C --- FT4 --- K40036 CE ELECTRICAL CHARACTERISTICS CONDUCTOR DCR: 5.54 Ω/100m (16.9 Ω/Mft) MAX PHYSICAL CHARACTERISTICS CABLE WEIGHT: 215 lbs/1000ft (320 kg/km) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADD UL TO LISTING 04/27/98 VB B UPDATE FORMAT & PRINT 11/30/05 JS C CHG JKT DIA & AWM TO PLTC; UPDATE PRINT, WT 03/22/07 JS D CHG BRD TO #34; ADJ JKT DIA; DEL CSA; ADD ROHS 12/28/07 JS Date: 04/09/98 Page 1 of 1 Part Number: M57325 Orig: Review: PRIMARIES: CONDUCTOR: 22 AWG (7/30) BARE COPPER P7 BLACK & ORANGE LAY OVERALL FOAMED POLYPROPYLENE TAPE, BARRIER: BRAID SHIELD: 32 AWG TINNED COPPER, 90% COVERAGE JACKET: COMPOUND: THERMOPLASTIC ELASTOMER CE - LOW VOLTAGE DIRECTIVE LEGEND: MOHAWK E M58506 22 AWG (.35 mm sq) P28 ORANGE & YELLOW CABLE WEIGHT: 383 lbs/1000ft (569 kg/km) Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 37 PAIR SHIELDED CABLE K40205 22 AWG / 37 PR CONSTRUCTION COLOR CODE P1 BLACK & RED INSULATION: .010” OF SEMI-RIGID PVC P2 BLACK & WHITE NOMINAL DIAMETER: .050” P3 BLACK & GREEN PAIR P4 BLACK & BLUE ASSEMBLY: 2 PRIMARIES TWISTED IN A 1.5” LEFT HAND LAY P5 BLACK & YELLOW CABLE P6 BLACK & BROWN ASSEMBLY: 37 PAIRS CABLED WITH AN 8.25” LEFT HAND P8 RED & WHITE 25% OVERLAP P9 RED & GREEN DRAIN WIRE: 22 AWG (7/30) TINNED COPPER P10 RED & BLUE P11 RED & YELLOW P12 RED & BROWN P13 RED & ORANGE NOMINAL OD: .774" (19.66 mm) P14 GREEN & WHITE COLOR: BLACK P15 GREEN & BLUE RATINGS: 80°C, 300V P16 GREEN & YELLOW LISTING/ UL TYPE PLTC - 80C P17 GREEN & BROWN RATINGS: NON CSA P18 GREEN & ORANGE P19 WHITE & BLUE P20 WHITE & YELLOW 37PR (UL) TYPE PLTC 80C --- K40205 CE P21 WHITE & BROWN (WITH SEQUENTIAL FOOTAGE MARKERS P22 WHITE & ORANGE EVERY 2 FEET & DATE CODE) P23 BLUE & YELLOW P24 BLUE & BROWN P25 BLUE & ORANGE P26 BROWN & YELLOW ELECTRICAL CHARACTERISTICS P27 BROWN & ORANGE CONDUCTOR DCR: 5.54 Ω/100m (16.9 Ω/Mft) MAX P29 VIOLET & ORANGE P30 VIOLET & RED P31 VIOLET & WHITE PHYSICAL CHARACTERISTICS P32 VIOLET & DK. GREEN P33 VIOLET & LT. BLUE P34 VIOLET & YELLOW P35 VIOLET & BROWN P36 VIOLET & BLACK P37 GRAY & WHITE MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A REVISED FINAL OD, CHG AWG ON BRAID, NON CSA 12/06/07 VB Date: 11/29/07 Page 1 of 1 Part Number: M58506 Orig: Review: Hybrid / Composite Cable Specifications WALL THICKNESS: .050" (1.27 mm) RATINGS: CSA AWM I/II A/B FT4 - 80°C, 300V ASSEMBLY: 2 PRIMARIES TWISTED IN A LEFT HAND LAY NOMINAL DIAMETER: .085” (2.15 mm) PAIR PAIR #2: WHITE & BLACK (22 AWG) PAIR #4: WHITE & BROWN (16 AWG) ELECTRICAL CHARACTERISTICS LAY Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 1 PAIR 16 AWG & 3 PAIR 22 AWG SHIELDED CABLE K40230 16AWG/1PR 22AWG/3PR Jacket Braid Shield Component A Conductor Component B Shielded Pair Drain Wire Shield Tape CONSTRUCTION COMPONENT A (TOTAL THREE) JACKET: MATERIAL: THERMOPLASTIC ELASTOMER PRIMARIES: COND: 22 AWG (.38 mm2) (19/34) TINNED COPPER NOMINAL OD: .340” (8.63 mm) INSULATION: .010” (.25 mm) OF PVC COLOR: GRAY SHEATH: .003" (.076 mm) OF NYLON NOMINAL DIAMETER: .056” (1.42 mm) PAIR LISTING/ UL PLTC-ER 105°C, 300V CE - LOW VOLTAGE DIRECTIVE COMPONENT B (TOTAL ONE) PRIMARIES: COND: 16 AWG (1.32 mm2) (26/30) TINNED COPPER INSULATION: .010” (.25 mm) OF PVC SHEATH: .003" (.076 mm) OF NYLON PAIR COLOR CODE PAIR #1: RED & BLACK (22 AWG) ASSEMBLY: 2 PRIMARIES TWISTED IN A 2.5" LEFT HAND LAY PAIR #3: GREEN & BLACK (22 AWG) DRAIN WIRE: 22 AWG (19/34) TINNED COPPER SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, 25% OVERLAP, 100% COVERAGE, ALUM SIDE IN CABLE CONDUCTOR DCR: 15.0 Ω/100m (45.7 Ω/Mft) MAX 22 AWG ASSEMBLY: 4 PAIRS CABLED TOGETHER IN A 4.5" LEFT HAND CONDUCTOR DCR: 4.34 Ω/100m (13.2 Ω/Mft) MAX 16 AWG SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, 25% OVERLAP, 100% COVERAGE, ALUM SIDE OUT DRAIN WIRE: 22 AWG (19/34) TINNED COPPER BRAID: #36 AWG TINNED COPPER, 80% COV PRINT LEGEND: MOHAWK E M58839 22 AWG (0.38 mm sq) 3PR & 16 AWG (1.32 mm sq) 1PR (UL) TYPE PLTC-ER SUN RES 105C --- LL CSA AWM I/II A/B 80C 300V FT4 --- ELECTRIFLEX K40230 CE (W/SEQUENTIAL FOOTAGE MARKS & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. A ADDED CSA LISTING 02/22/08 VB B REVISE PRINT; ADD PART NUMBER 05/02/08 JS C REVISE PRINT; ADD K # 05/09/08 JS Date: 09/26/07 Page 1 of 1 Part Number: M58839 Orig: Review: COMPOSITE CABLE WITH FILLERS IN A 5.75” LEFT HAND LAY OVERALL FOAMED POLYPROPYLENE, BARRIER: COPPER COPPER CONDUCTOR DCR: CONDUCTOR DCR: 2.82 Ω/1000’ (COMPONENT A) 6.59 Ω/1000’ (COMPONENT B) SHEATH: .0045” (.11 mm) WALL OF NYLON P1 BLUE #5 & #6 APPLICATIONS SURFACE FACING OUT AGAINST DRAIN • ROBOTICS AND PLANT AUTOMATION EQUIPMENT 20° ANGLE • MATERIAL HANDLING EQUIPMENT Cabling Excellence for Open Architecture Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations. SPECIFICATION 4 COND #14 AWG, 2 PAIR #18 AWG, K40162 14AWG/4C | 18AWG/2PR Jacket Pair Shield Conductor Insulation Barrier Filler Overall Shield FINAL CABLE CONSTRUCTION ASSEMBLY: THE ABOVE COMPONENTS ARE CABLED COMPONENT A (4 TOTAL) PRIMARIES: CONDUCTOR: #14 AWG (2.11 mm²) (105/34) BARE 25% OVERLAP INSULATION: .016” (.41 mm) WALL OF 105°C PVC SHIELD: #34 AWG TINNED COPPER BRAID, 86% COV. SHEATH: .005” (.13 mm) WALL OF NYLON JACKET: MATERIAL: ORANGE THERMOPLASTIC ELASTOMER NOMINAL DIAMETER: .116” (2.95 mm) NOMINAL WALL: .062” (1.57 mm) COLOR CODE: 3/C BLACK & NUMBERED #1 - #3 IN WHITE INK DIAMETER: .621” (15.77 mm) 1/C GREEN WITH YELLOW STRIPE LISTING/ UL TYPE TC-ER - 90°C, 600V RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CE - LOW VOLTAGE DIRECTIVE COMPONENT B (2 TOTAL) PRIMARIES: CONDUCTOR: #18 AWG (0.82 mm²) (41/34) BARE ELECTRICAL CHARACTERISTICS INSULATION: .016” (.41 mm) WALL OF 105°C PVC NOMINAL DIAMETER: .088” (2.23 mm) COLOR CODE: BLUE & NUMBERED #5 - #8 PHYSICAL CHARACTERISTICS PAIR TEMP. RATING: -25° to +90°C ASSEMBLY: 2 PRIMARIES TWISTED IN A 2.5” LEFT HAND LAY VOLTAGE RATING: 600 VOLTS P2 BLUE #7 & #8 CABLE WEIGHT: 273 lbs/M’ (406 kg/km) SHIELD: OVERALL ALUMINUM/POLYESTER TAPE, BENDING RADIUS: 6.2” (157 mm) MIN (10 x CABLE OD) 25% OVERLAP, 100% COVERAGE, ALUMINIZED DRAIN: 20 AWG (10/30) TINNED COPPER • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING SHIELD: 36 AWG TINNED COPPER BRAID, 86% COVERAGE, • MACHINE TOOLS ISOLATION: OVERALL POLYESTER TAPE, 50% OVERLAP • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE TRAYS - EXPOSED RUNS PRINT: MOHAWK E163873 M57997 -UL 1277 TC-ER - 600V (UL) 14 AWG (2.11 mm sq) 4 COND THHN - 18 AWG (0.82 mm sq) 2 PRS TFFN --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRI-FLEX K40162 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE) MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA (978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com This document is the property of Mohawk. The information contained herein is considered proprietary and not to be reproduced by any means without written consent of Mohawk. Rev Description Date Init. E DELETE SEQ FOOTAGE MARKS & DATE CODE 12/10/03 JS F UPDATE HEADER/FOOTER, PRINT & LISTINGS 05/02/05 JS G UPDATE CSA TEMP, TEMP RATING, PRINT 05/31/06 JS H ADJ TEMP; ADD APPS, BEND, SQ FT/CODE, ROHS 11/14/07 JS Date: 09/18/00 Page 1 of 1 Part Number: M57997 Orig: Review: COMPANY OVERVIEW CONTACT INFORMATION 8 AWG Cable Specifications 8 AWG / 4C 10 AWG Cable Specifications 10 AWG / 3C 10 AWG / 4C 10 AWG / 6C 12 AWG Cable Specifications 12 AWG / 3C 12 AWG / 4C 12 AWG / 4C 12 AWG / 7C 14 AWG Cable Specifications 14 AWG / 3C 14 AWG / 3C 14 AWG / 4C 14 AWG / 4C 14 AWG / 5C 14 AWG / 7C 16 AWG Cable Specifications 16 AWG / 3C 16 AWG / 3C 16 AWG / 4C 16 AWG / 4C 16 AWG / 7C 16 AWG / 7C 16 AWG / 7C 16 AWG / 7C 16 AWG / 12C 16 AWG / 12C 16 AWG / 12C 16 AWG / 18C 16 AWG / 19C 16 AWG / 25C 16 AWG / 25C 16 AWG / 33C 16 AWG / 37C 22 AWG Cable Specifications 22 AWG / 24C Communication / Shielded Cable Specifications 20 AWG / 3C 20 AWG / 2 PR 20 AWG / 3 PR 20 AWG / 16 PR 22 AWG / 3 PR 22 AWG / 3 PR 22 AWG / 17 PR 22 AWG / 37 PR Hybrid / Composite Cable Specifications 16AWG/1PR 22AWG/3PR 14AWG/4C | 18AWG/2PR