Air Cooler Data Sheet

May 1, 2018 | Author: Anonymous | Category: Documents
Report this link


Description

- 402 SHEET 1 REV SERVICE ITEM NO. 1 SURFACE/ITEM-FINNED TUBE m² 2 PLANT LOCATION SURFACE/ITEM-BARE TUBE m² 3 MTD, EFFECTIVE °C 4 HEAT EXCHANGED 10^6.kcal/h TRANSFER RATE-FINNED (kcal/h)/(m².°C) 5 BARE TUBE SERVICE (kcal/h)/(m².°C) 6 TYPE DRAFT: INDUCED FORCED BARE TUBE CLEAN (kcal/h)/(m².°C) 7 BAY SIZE (W X L) m NO OF BAYS/ITEM 8 9 FLUID NAME 10 TOTAL FLUID ENTERING kg/h TEMPERATURE °C 11 TOTAL FLUID Rel. Mol. Mass TOTAL VAPOR | Mol. Mass kg/h 12 DEW POINT °C VAPOR HCBN kg/h 13 POUR POINT °C VAPOR H2 kg/h 14 BUBBLE POINT °C VAPOR H2O kg/h 15 FREEZE POINT °C NONCONDENSIBLES kg/h 16 LATENT HEAT LIQUID | Rel. Mol. Mass kg/h 17 INLET PRESSURE kg/cm²[g] Water/Other Liq. | Mol. Mass kg/h 18 PRESSURE DROP (Allow | Calc) kg/cm²[g] Mol% H2(V) | Mol% H2S(Tot) 19 VELOCITY (Allow | Calc) m/s DENSITY (V | L) kg/m3 20 INSIDE FOULING RESISTANCE h.m².°C/kcal SPECIFIC HEAT (V | L) kcal/(kg.°C) 21 THERMAL COND (V | L) kcal/(h.m.°C) 22 VISCOSITY (V | L) cP 23 24 AIR INLET TEMPERATURE (design dry bulb) °C FACE VELOCITY m/min 25 AIR FLOW RATE/ITEM kg/h MINIMUM DESIGN AMBIENT TEMP °C 26 AIR FLOW RATE/ITEM norm m³/m ALTITUDE m 27 MASS VELOCITY (net free area) kg/s-m² STATIC PRESSURE mm Hg 28 AIR OUTLET TEMPERATURE °C AIR FLOW RATE/FAN act m³/m 29 AIR SIDE FOULING RESISTANCE h.m².°C/kcal 30 31 DESIGN PRESSURE kg/cm²[g] HEATING COIL REQUIRED 32 TEST PRESSURE NO OF TUBES OD mm 33 DESIGN TEMPERATURE °C TUBE MATERIAL 34 MIN. DESIGN METAL TEMP. °C FIN MATERIAL AND TYPE 35 VACUUM DESIGN PRESSURE kg/cm²[a] THICKNESS mm 36 VACUUM DESIGN TEMPERATURE °C PRESSURE DESIGN CODE 37 STAMP? YES NO 38 TUBE BUNDLE HEATING FLUID FLOW RATE kg/h 39 SIZE (W x L) m TEMPERATURE (in/out) / °C 40 NO./BAY NO TUBE ROWS * INLET PRESSURE kg/cm²[g] 41 BUNDLES: IN SERIES IN PARALLEL PRESSURE DROP (allow/calc) / kg/cm²[g] 42 STRUCTURE MOUNTING GRADE PIPERACK DESIGN PRESSURE kg/cm²[g] 43 PIPEREACK BEAMS (c-c distance) m DESIGN TEMPERATURE °C 44 LADDERS, WALKWAYS, PLATFORMS YES NO INLET/OUTLET NOZZLE SIZE / NPS 45 STRUCTURE SURF PREP/COATING 46 HEADER SURF PREP/COATING HEADER 47 TYPE 48 LOUVER MATERIAL 49 MATERIAL CORROSION ALLOWANCE mm 50 ACTION CONTROL: AUTO MANUAL NO OF PASSES 51 ACTION TYPE: OPPOSED PARALLEL 52 * GIVE TUBE COUNT FOR EACH PASS IF IRREGULAR 53 402-0 TZ-402-02-0 UOP LLC • 25 East Algonquin Road • Des Plaines, Illinois 60017-5017 USA Killed Carbon Steel (Std 3-11) 0 CODE DESIGN, MATERIALS, AND CONSTRUCTION PROJECT SPECIFICATION APVD AIR COOLED EXCHANGERS APVD REV DATE BY 10.8 0.0003 REV DATE BY 158 60 13.5 0.280 78.6 40.937233 1507 97 2.0 93 2.0 136 18.0 26 18.0 35755 81.1 85 18.0 528.8 8.206 622.3 9.12 2.03 54.56 2.03 0.029 0.568 27.340 0.612 0.586 0.094 0.061 0.109 0.712 PERFORMANCE DATA - AIR SIDE 0.0004 -4 150 PERFORMANCE DATA - TUBE SIDE 4.55 IN OUT 0.010 70.7 1626 19.3 N ot e: T he in fo rm at io n in th is do cu m en t i s c on fid en tia l a nd th e pr op er ty o f U O P LL C a nd m us t n ot b e di sc lo se d to o th er s o r r ep ro du ce d in a ny m an ne r o r u se d fo r a ny p ur po se w ha tso ev er w ith ou t i ts w rit te n pe rm iss io n. 190 HYDROCARBON, HYDROGEN & H2O 37466 70.7 Middle East 25 0.1 0.125 0.011 0.213 50 37466 122-MEA-06STRIPPER CONDENSER - 402 SHEET 2 REV ITEM NO. 1 2 HEADER (CONTINUED) NO./BUNDLE LENGTH m 3 SLOPE mm/m PITCH mm 4 PLUG MATERIAL LAYOUT 5 GASKET MATERIAL FIN 6 NOZZLE TYPE 7 INLET MATERIAL 8 OUTLET STOCK THICKNESS mm 9 VENT SELECTION TEMPERATURE 10 DRAIN OD mm FREQUENCY No/mm 11 MISC CONN'S: TI PI PRESSURE DESIGN CODE: 12 CHEMICAL CLEANING STAMP? YES NO 13 MIN. TUBE WALL THICKNESS mm SPECIFICATIONS 14 TUBE 15 MATERIAL 16 OD mm MIN. WALL THICKNESS mm 17 18 19 FAN SPEED rpm SERVICE FACTOR 20 MANUFACTURER & MODEL ENCLOSURE 21 NO/BAY SPEED rpm VOLTAGE PHASE CYCLE HZ 22 DIAMETER m NO OF BLADES FAN NOISE LEVEL (allow/calc), at m / Db(A) 23 ANGLE degrees 24 PITCH ADJUSTMENT SPEED REDUCER 25 BLADE MATERIAL HUB MATERIAL TYPE 26 POWER/FAN@DES TEMP kW @ MIN AMBIENT kW MANUFACTURER & MODEL 27 MAX ALLOW/CALC TIP SPEED / m/min NO/BAY 28 FAN CONTROLS None SERVICE FACTOR SPEED RATIO / 1 29 Auto-Variable Pitch Variable Speed Drive SUPPORT: STRUCTURE PEDESTAL 30 DRIVER VIBRATION SWITCH: YES NO 31 TYPE ENCLOSURE: 32 MANUFACTURER & MODEL 33 NO/BAY POWER DRIVER 34 35 36 AIR RECIRCULATION: LOUVERS: 37 NONE INTERNAL EXTERNAL INLET OUTLET BYPASS 38 OVER: SIDE END POSITIONER: YES NO 39 DEGREE CONTROL OF OUTLET PROCESS TEMP. SIGNAL AIR PRESSURE 40 MAX COOLING, +/- / FROM TO 41 ACTION ON CONTROL SIGNAL FAILURE 42 FAN PITCH: MINIMUM MAXIMUM LOCKUP FROM TO 43 LOUVERS OPEN CLOSE LOCKUP SUPPLY AIR PRESSURE 44 ACTUATOR AIR SUPPLY MAX. MIN. 45 FAN: NONE POSITIONER BIAS RELAY MAX. MIN. 46 47 48 PLOT AREA (W x L) / m TOTAL SHIPPING WT. kg 49 BUNDLE MASS kg 50 51 52 53 402-0 TZ-402-02-0 UOP LLC • 25 East Algonquin Road • Des Plaines, Illinois 60017-5017 USA Electric Motor PROJECT SPECIFICATION APVDREV DATE BY APVD REV DATE BY SHIPPING CONTROLS - AIR SIDE Killed Carbon Steel (Std 3-11) 50415 3 MECHANICAL EQUIPMENT API 661/ISO 13706 ASME BPVC Section VIII, Div 1 150 RF CLASS & FACING 150 RF 12.0 AIR COOLED EXCHANGERS 122-MEA-06 N ot e: T he in fo rm at io n in th is do cu m en t i s c on fid en tia l a nd th e pr op er ty o f U O P LL C a nd m us t n ot b e di sc lo se d to o th er s o r r ep ro du ce d in a ny m an ne r o r u se d fo r a ny p ur po se w ha tso ev er w ith ou t i ts w rit te n pe rm iss io n. No. Size (NPS) - 402 SHEET 3 REV SERVICE ITEM NO. 1 2 3 4 5 Properties at 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Properties at 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Properties at 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 402-0 TZ-402-02-0 UOP LLC • 25 East Algonquin Road • Des Plaines, Illinois 60017-5017 USA BY STRIPPER CONDENSER Normalized Normalized 122-MEA-06 REV DATE REV DATE BY APVD PROJECT SPECIFICATION APVD Frac. Press. Temp Surface Critical Critical Cond. Heat Cond. Heat Tension Density Visc. Thermal SpecificDensity Visc. Thermal SpecificTemp. VAPOR TOTAL LIQUID Thermal Specific Temp Surface Critical Critical Tension TOTAL LIQUID Specific Density Visc.Temp. Density Visc. Thermal Vapor Specific Cond. Heat Specific Visc. ThermalDensity Normalized CriticalMass Frac. Enthalpy Heat HOT SIDE PROPERTIES VAPOR TOTAL LIQUID Temp. Density Visc. Thermal Surface TempTension Press.Cond. Enthalpy Vapor Frac. VAPOR Enthalpy Cond. Heat Mass Vapor Cond. Heat Press. AIR COOLED EXCHANGERS N ot e: T he in fo rm at io n in th is do cu m en t i s c on fid en tia l a nd th e pr op er ty o f U O P LL C a nd m us t n ot b e di sc lo se d to o th er s o r r ep ro du ce d in a ny m an ne r o r u se d fo r a ny p ur po se w ha tso ev er w ith ou t i ts w rit te n pe rm iss io n. Mass Critical - 402 SHEET 4 REV SERVICE ITEM NO. 1 2 3 4 5 See UOP Standard Specification 4-13. 6 7 8 9 10 11 12 13 14 15 Tube side 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 402-0 TZ-402-02-0 DATE BY BUNDLE ARRANGEMENT REQUIREMENTS: None APVDREVUOP LLC • 25 East Algonquin Road • Des Plaines, Illinois 60017-5017 USA APVD Limit number of tube bundles to 2, 4, 8, 16 … 2nth Use even number of tube bundles STRIPPER CONDENSER 122-MEA-06 PROJECT SPECIFICATION REV DATE BY 1. Design for hydrogen service per UOP Standard Specification 4-13 Section 4.1. 2. Design for wet H2S service per UOP Standard Specification 4-13 Section 4.2. 3. Provide 3/16" (5 mm) corrosion allowance on headers. 1 8 No. Size, in 1 8 Inlet Outlet No. Size, in NOTES N ot e: T he in fo rm at io n in th is do cu m en t i s c on fid en tia l a nd th e pr op er ty o f U O P LL C a nd m us t n ot b e di sc lo se d to o th er s o r r ep ro du ce d in a ny m an ne r o r u se d fo r a ny p ur po se w ha tso ev er w ith ou t i ts w rit te n pe rm iss io n. AIR COOLED EXCHANGERS LINE SIZES


Comments

Copyright © 2024 UPDOCS Inc.