REHABILITATION OF YANBU SOUTHTERMINAL PROJECTS BI # 10-00567 Material Receiving, Handling, Storage and preservation Inspection of Electrical & Instrumentation Cables 1 Presented By: SAIFUDDIN CHAUDHRY ID/WRPIS. 2 Contents Types of Cables Electrical Cables Metallic I&C Cable Documents Required for Material Receiving Inspection Cable Storage. Handling and Preservation General Requirement for LV Power Cable General Requirement for MV Power Cable General Requirement for HV Power Cable General Requirement for Metallic Instrumentation and Control Cable . .001 kV to 35 kV).3 Types of Cables Electrical Cables Low Voltage Power Cable and Building Wire (up to 1 kV). Multi pair / triad.001 kV to 69 kV). Metallic Instrumentation and Control Cable I&C Copper Cable . Instrument Cable .Unshielded Single Twisted Pair / Triad.Coaxial and Twin axial Data Cable. I &C Copper Cable -Thermocouple Extension Cable. Multi pair / triad. High Voltage Cable (35. I&C Copper Cable -Shielded Single Twisted Pair / Triad. Very High Voltage Cable (above 69 kV). Medium Voltage Cable and Conductors (1. Material Requisition. Material Technical Approval Letter. . SAIC (Saudi Aramco Inspection Checklist). IFC Drawings.4 Documents Required for Material Receiving Inspection SATIP (Saudi Aramco Typical Inspection Plan). Material Test Certificate. Vendor Approval Letter. Delivery Note. Purchase Order. SATR (Saudi Aramco Test Report). SAIC-P-3211. SATIP-P-104-10 for HV Cable (35.5 References for Material Receiving Inspection SCHEDULE-Q SATIP (Saudi Aramco Typical Inspection Plan) SATIP-P-104-01 for LV Power Cable and Building Wire (up to 1 kV). SAIC-P-3212 and SATR-P-3207 for MV Power Cable. SAIC-J-6603. SAIC-P-3220 and SATR-P-3215 for VHV Power Cable. 3202. 3205 and SATR-P-3201. SAIC-J-6602. SATIP-P-104-11 for VHV Cable (above 69 kV). SAIC-J-6604 and SATR-J-6601 for I&C Cable. SAIC-P-3216 and SATR-P-3211 for HV Power Cable.001 kV to 69 kV). 3203. 3202 for LV Power Cable.001 kV to 35 kV). . SATIP-J-902-01 for Metallic I&C Cable SAIC (Saudi Aramco Inspection Checklist) and SATR (Saudi Aramco Test Report) SAIC-3201. SATIP-P-104-02 for MV Cable and Conductors (1. 3204. SAIC-J-6601. Material Test Certificate. Material Requisition: A material requisition form lists the items to be picked from inventory and used in the production process or in the provision of a service to a customer. and agreed prices for products or services. usually for a specific job. A letter that certifies the supplier is approved by Saudi Aramco.6 Documents Required for Material Receiving Inspection Purchase Order. and quantity of the goods delivered. indicating types. A document that certifies that the supplied material is according to all applicable standards. Drawings that justifies the quantity and use of received material. IFC Drawings. Vendor Approval Letter. A commercial document and first official offer issued by a buyer to a seller. A letter that certifies that supplied material is approved for the specific project. Material Technical Approval Letter. Delivery Note. quantities. A document accompanying a shipment of goods that lists the description. . or handling. Manufacturer's special handling instructions shall be followed. . Cable reels shall be supported off the ground and provided with a weatherproof (i. Cable reels shall be stored away from chemicals and petroleum products. rain and dust-tight) cover. unloading. Storage and Preservation Firm dry support shall be provided for storage of cable reels.e. Handling and Preservation Handling Cable reels shall be checked for damage by store yard personnel prior to acceptance of shipment.. Cable ends shall be sealed (water and dust-proof seals) and firmly secured during shipping and storage.7 Cable Storage. Cable reels shall be shipped and handled on edges of flanges only (not on flat side of flanges). Cable and wire for industrial locations shall be stranded (regardless of size).5 mm² (14 AWG). or larger.quantity and size Cables with a neutral conductor that is smaller than ungrounded . Manufacturer’s name. Marking . trademark.8 General Requirement for LV Power Cable Cable and wire shall be rated 600 V. Control conductor cross-sectional-area shall be 2. Cable and wire shall have a minimum temperature rating of 90°C dry locations and 75°C for wet locations.Cable and wire shall be externally marked by the manufacturer to indicate Maximum rated voltage Type letters for the cable and/or wire. Power conductor cross-sectional-area shall be 4 mm² (12 AWG). or other distinctive marking M/C Cable . or larger. Conductor and insulation screening is required for all cables. if IEC cable is specified. is prohibited.9 General Requirement for MV Power Cable Each phase of multi-conductor cables shall be permanently identified. and vice versa. suitable for 90°C maximum rated conductor temperature. shall be heavy duty wood reels. alternatively. Reels shall be made of steel. The outer sheath (jacket) shall be polyvinyl chloride (PVC). Substitution of IEC cable with AEIC cable. All cables shall have a continuous overall outer nonmetallic sheath (jacket). . or. Minimum size of MV cable shall be 10mm² (8 AWG). lists. High Voltage Cable shall be in accordance with the Saudi Aramco- approved project-specific design drawings. schedules. . diagrams. Check that the end cap (seal) of cable are heat-shrinkable. Check that the cables are supplied from acceptable manufacturers. Wires and cables shall have copper conductors. The sizing of cables rated 69 kV and above shall be per IEC 60287.10 General Requirement for HV Power Cable Incoming High Voltage Cable shall be visually inspected for damage / defects occurred during transportation. Aluminum conductors are permitted to be used in community areas for sizes 25 mm² or larger. databases. and associated design documents. Primary Insulation Voltage Rating: 300 V for Type PLTC and Type ITC Cable 600 V for Type TC Cable Jacket Material: Flame retardant PVC. 7 strands minimum. circular copper. minimum temperature rating 90°C. per ASTM B33.11 General Requirement for Metallic Instrumentation and Control Cable Conductor: Stranded. Jacket Color: Non-intrinsically safe applications: Manufacturer's standard other than blue. per ASTM B3. Intrinsically safe applications: Blue FF Application: Orange . if primary insulation may corrode unprotected copper. tinned. 12 THANK YOU .
Comments
Report "Material Receiving Inspection of Electrical and Instrumentation Cables Autosaved"